# ExStik® II Conductivity Kit
## Overview
A waterproof meter that measures Conductivity, TDS, Salinity, and Temperature. Includes calibration standards, sample cups, and a carrying case.
## Features
· Measurement Ranges: Conductivity, TDS, Salinity, and Temperature.
· Units of Measure: μS/cm, mS/cm, ppm, ppt, mg/L, g/L, °F, °C.
· Display: 3-1/2 digit (2000 count) digital display with analog bargraph.
· Memory: Stores up to 15 labeled readings.
· Calibration: Self-calibration on power up, auto standard recognition (84μS/cm, 1413μS/cm, 12880μS/cm).
· Protection: Waterproof (IP57).
· Compensation: Automatic Temperature Compensation (2% per °C).
· Power: Four 3V CR-2032 batteries.
· Included Accessories: Sensor, protective cap, calibration standards, weighted base, 3 sample plastic cups, neckstrap, carrying case.
## Specifications
Conductivity
· Range: 0 to 199.9μS/cm, 200 to 1999μS/cm, 2.00 to 19.99mS/cm
· Resolution: 0.1μS/cm, 1μS/cm, 0.01mS/cm
· Accuracy: ±2% FS
TDS
· Range: 0 to 99.9ppm (mg/L), 100 to 999ppm (mg/L), 1.00 to 9.99ppt (g/L)
· Resolution: 0.1ppm (mg/L), 1ppm (mg/L), 0.01ppt (g/L)
· Accuracy: ±2% FS
Salinity
· Range: 0 to 99.9ppm (mg/L), 100 to 999ppm (mg/L), 1.00 to 9.99ppt (g/L)
· Resolution: 0.1ppm (mg/L), 1ppm (mg/L), 0.01ppt (g/L)
· Accuracy: ±2% FS
Temperature
· Range: 32° to 149°F (0° to 65°C)
· Resolution: 0.1°
· Accuracy: ±1.8°F/1°C
## Dimensions & Weight
· Meter: 1.4 x 6.8 x 1.6" (36 x 173 x 41mm), 3.8 oz (110g)
· Kit: 9.5 x 6.8 x 2.8" (241 x 173 x 71mm), 1.56 lbs (708g)
## Ordering Information
· EC410: ExStik® Conductivity/TDS/Salinity Kit
· EC400: ExStik® Conductivity/TDS/Salinity Meter
· EC405: Spare Conductivity Cell
· EC-84-P: 84μS Conductivity Standard
· EC-1413-P: 1413μS Conductivity Standard
· EC-12880-P: 12880μS Conductivity Standard
· EX007: Spare sample solution cups
· EX010: Extension Cable, 3ft (1 Meter)
· EX050: Extension Cable, 16ft (5 Meters)
*Note: ExStik® Conductivity cell is not interchangeable with other ExStik ® meters.
# ExStik® II Conductivity Kit
## Overview
A waterproof meter that measures Conductivity, TDS, Salinity, and Temperature. Includes calibration standards, sample cups, and a carrying case.
## Features
· Measurement Ranges: Conductivity, TDS, Salinity, and Temperature.
· Units of Measure: μS/cm, mS/cm, ppm, ppt, mg/L, g/L, °F, °C.
· Display: 3-1/2 digit (2000 count) digital display with analog bargraph.
· Memory: Stores up to 15 labeled readings.
· Calibration: Self-calibration on power up, auto standard recognition (84μS/cm, 1413μS/cm, 12880μS/cm).
· Protection: Waterproof (IP57).
· Compensation: Automatic Temperature Compensation (2% per °C).
· Power: Four 3V CR-2032 batteries.
· Included Accessories: Sensor, protective cap, calibration standards, weighted base, 3 sample plastic cups, neckstrap, carrying case.
## Specifications
Conductivity
· Range: 0 to 199.9μS/cm, 200 to 1999μS/cm, 2.00 to 19.99mS/cm
· Resolution: 0.1μS/cm, 1μS/cm, 0.01mS/cm
· Accuracy: ±2% FS
TDS
· Range: 0 to 99.9ppm (mg/L), 100 to 999ppm (mg/L), 1.00 to 9.99ppt (g/L)
· Resolution: 0.1ppm (mg/L), 1ppm (mg/L), 0.01ppt (g/L)
· Accuracy: ±2% FS
Salinity
· Range: 0 to 99.9ppm (mg/L), 100 to 999ppm (mg/L), 1.00 to 9.99ppt (g/L)
· Resolution: 0.1ppm (mg/L), 1ppm (mg/L), 0.01ppt (g/L)
· Accuracy: ±2% FS
Temperature
· Range: 32° to 149°F (0° to 65°C)
· Resolution: 0.1°
· Accuracy: ±1.8°F/1°C
## Dimensions & Weight
· Meter: 1.4 x 6.8 x 1.6" (36 x 173 x 41mm), 3.8 oz (110g)
· Kit: 9.5 x 6.8 x 2.8" (241 x 173 x 71mm), 1.56 lbs (708g)
## Ordering Information
· EC410: ExStik® Conductivity/TDS/Salinity Kit
· EC400: ExStik® Conductivity/TDS/Salinity Meter
· EC405: Spare Conductivity Cell
· EC-84-P: 84μS Conductivity Standard
· EC-1413-P: 1413μS Conductivity Standard
· EC-12880-P: 12880μS Conductivity Standard
· EX007: Spare sample solution cups
· EX010: Extension Cable, 3ft (1 Meter)
· EX050: Extension Cable, 16ft (5 Meters)
*Note: ExStik® Conductivity cell is not interchangeable with other ExStik ® meters.
| Part No. | EC400 |
| Manufacturer | EXTECH |
| Size | 183 Kbytes |
| Pages | 1 page |
| Description | ExStik II Conductivity Kit |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |