| Zakładka z wyszukiwarką danych komponentów |
|
ST7LITE30 Arkusz danych(PDF) 113 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST7LITE30 Arkusz danych(HTML) 113 Page - STMicroelectronics |
|
113 / 167 page ![]() ST7LITE3 113/167 LINSCI ™ SERIAL COMMUNICATION INTERFACE (LIN Mode) (Cont’d) 11.5.10 LIN Mode Register Description STATUS REGISTER (SCISR) Read Only Reset Value: 1100 0000 (C0h) Bits 7:4 = Same function as in SCI mode, please refer to Section 11.5.8 SCI Mode Register De- scription. Bit 3 = LHE LIN Header Error. During LIN Header this bit signals three error types: – The LIN Synch Field is corrupted and the SCI is blocked in LIN Synch State (LSF bit=1). – A timeout occurred during LIN Header reception – An overrun error was detected on one of the header field (see OR bit description in Section 11.5.8 SCI Mode Register Description)). An interrupt is generated if RIE=1 in the SCICR2 register. If blocked in the LIN Synch State, the LSF bit must first be reset (to exit LIN Synch Field state and then to be able to clear LHE flag). Then it is cleared by the following software sequence : an access to the SCISR register followed by a read to the SCIDR register. 0: No LIN Header error 1: LIN Header error detected Note: Apart from the LIN Header this bit signals an Over- run Error as in SCI mode, (see description in Sec- tion 11.5.8 SCI Mode Register Description) Bit 2 = NF Noise flag In LIN Master mode (LINE bit = 1 and LSLV bit = 0) this bit has the same function as in SCI mode, please refer to Section 11.5.8 SCI Mode Register Description In LIN Slave mode (LINE bit = 1 and LSLV bit = 1) this bit has no meaning. Bit 1 = Bit 1 = FE Framing error. In LIN slave mode, this bit is set only when a real framing error is detected (if the stop bit is dominant (0) and at least one of the other bits is recessive (1). It is not set when a break occurs, the LHDF bit is used instead as a break flag (if the LHDM bit=0). It is cleared by a software sequence (an access to the SCISR register followed by a read to the SCIDR register). 0: No Framing error 1: Framing error detected Bit 0 = PE Parity error. This bit is set by hardware when a LIN parity error occurs (if the PCE bit is set) in receiver mode. It is cleared by a software sequence (a read to the sta- tus register followed by an access to the SCIDR data register). An interrupt is generated if PIE=1 in the SCICR1 register. 0: No LIN parity error 1: LIN Parity error detected CONTROL REGISTER 1 (SCICR1) Read/Write Reset Value: x000 0000 (x0h) Bits 7:3 = Same function as in SCI mode, please refer to Section 11.5.8 SCI Mode Register De- scription. Bit 2 = PCE Parity control enable. This bit is set and cleared by software. It selects the hardware parity control for LIN identifier parity check. 0: Parity control disabled 1: Parity control enabled When a parity error occurs, the PE bit in the SCISR register is set. Bit 1 = Reserved Bit 0 = Same function as in SCI mode, please refer to Section 11.5.8 SCI Mode Register Description. 7 0 TDRE TC RDRF IDLE LHE NF FE PE 7 0 R8 T8 SCID M WAKE PCE PS PIE |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |