483 / 894 page ![]() Section 15 Serial Communication Interface with FIFO (SCIF) Rev. 1.00 Mar. 18, 2008 Page 459 of 866 REJ09B0451-0100 (5) Data Reception Figure 15.10 shows an example of the data reception flowchart. Read FLSR Receive data ready interrupt Read receive FIFO Read FLSR Error processing (Transmission/reception standby flow) BI = 1, FE = 1, PE = 1, or OE = 1 DR = 0 No Yes [1] [2] [3] [4] [1] When data is received, a receive data ready interrupt occurs. Go to the data reception flow by using this interrupt trigger. [2] Confirm that the BI, FE, PE, and OE flags in FLSR are all cleared. If any one of these flags is set to 1, perform error processing. [3] Read the receive FIFO. [4] Check the DR flag in FLSR. When the DR flag is cleared and all of the data has been read, data reception is complete. Figure 15.10 Example of Data Reception Flowchart |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|