Zakładka z wyszukiwarką danych komponentów
  Polish  ▼
ALLDATASHEET.PL

X  

  • WRPP-KAA-R

  • AI
    The **WRPP-KAA-R** is a high-precision, industrial-grade **Thermocouple Temperature Sensor**, specifically a **Type K** (Nickel-Chromium / Nickel-Alumel) platinum-rhodium style assembly. It is designed for high-temperature measurements in harsh environments like furnaces, kilns, and chemical processing plants. --- ## 1. Technical Specifications Below are the primary electronic and physical characteristics of the WRPP-KAA-R sensor. | Feature | Specification | | :--- | :--- | | **Thermocouple Type** | Type K (Chromel / Alumel) | | **Temperature Range** | 0°C to 1300°C (Short term up to 1350°C) | | **Accuracy Class** | Class I or Class II (Standard industrial) | | **Protection Tube** | Corundum (High Alumina Ceramic) or Stainless Steel | | **Connection Head** | Waterproof Aluminum Alloy (Type KAA) | | **Output Signal** | Thermoelectromotive force (mV) | --- ## 2. Key Electronic Components The "Electronic" nature of this device refers to the **Seebeck Effect**—the generation of a voltage due to a temperature gradient. ### A. The Thermoelement (The Sensing Wire) The core consists of two dissimilar metal wires: * **Positive Pole (KP):** Nickel-Chromium alloy. * **Negative Pole (KN):** Nickel-Silicon (or Alumel) alloy. * **Function:** When the "hot junction" (tip) is heated, a micro-voltage (millivolts) is generated between the two wires, which is proportional to the temperature. ### B. KAA Junction Head The "KAA" in the model name refers to the specific **Terminal Box**: * **Material:** Die-cast aluminum. * **Terminals:** Contains ceramic terminal blocks with brass or copper binding posts. * **Protection:** IP65 or IP67 rated to prevent moisture from affecting the electrical resistance of the connection. ### C. Internal Insulation Because the sensor operates at high voltages (relative to sensitive electronics) and high heat, the internal wires are threaded through **ceramic insulators** (usually Alumina). This prevents a short circuit between the two wires before they reach the measurement tip. --- ## 3. Working Principle 1. **Thermal Input:** Heat is applied to the sensing tip (Hot Junction). 2. **Voltage Generation:** The temperature difference between the hot junction and the cold junction (at the terminal head) creates a voltage. 3. **Signal Transmission:** The millivolt signal is sent via compensation wires to a PLC (Programmable Logic Controller) or a Temperature Controller. 4. **Conversion:** The controller uses a lookup table to convert the specific mV reading (e.g., 41.276 mV for 1000°C) into a readable temperature value. --- ## 4. Installation and Wiring To ensure electronic accuracy, follow these standards: * **Polarity:** Ensure the positive (usually Green/Yellow) and negative (usually White/Blue) leads are connected correctly. * **Compensation Leads:** Always use **Type K Extension Wires**. Using standard copper wire will introduce a "parasitic junction" and cause significant measurement errors.
    ✨ Follow-up Questions
    • ⤷ What is the difference between Type K and Type S thermocouples in high-temperature applications?
    • ⤷ How do I calibrate a WRPP-KAA-R sensor using a PID controller?
    • ⤷ What are the common causes of signal drift in ceramic-sheathed thermocouples?