| Zakładka z wyszukiwarką danych komponentów |
|
AHF2805S/ES Arkusz danych(PDF) 7 Page - International Rectifier |
|
|
|||||||||||||||||||||||||||||
AHF2805S/ES Arkusz danych(HTML) 7 Page - International Rectifier |
|
7 / 17 page ![]() www.irf.com 7 AHF28XX Series Table III. Electrical Performance Characteristics - continued AHF2815S Notes to Specifications 1. Parameter guaranteed by line and load regulation tests. 2. Bandwidth guaranteed by design. Tested for 20 kHz to 2 MHz. 3. Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive in excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing as a short circuit during turn-on. 4. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall be guaranteed to the limits specified in Table III. 5. An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit protection and is the condition of maximum power dissipation. 6. Load step transition time between 2 and 10 microseconds. 7. Recovery time is measured from the initiation of the transient to where V OUT has returned to within ±1 percent of V OUT at 50 percent load. 8. Input step transition time between 2 and 10 microseconds. 9. Turn-on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the inhibit pin (pin 2) while power is applied to the input is unlimited. Limits Test Symbol Conditions -55°C ≤ Tc ≤ +125°C Vin = 28 Vdc ±5%, C L = 0 unless otherwise specified Group A Subgroups Device Types Min Max Unit 1000 mA to/from 2000mA 4,5,6 -800 +800 Output response to step transient load Changes 6 VO TLOAD 0 mA to/from 1000mA 4,5,6 All -1000 +750 mV pk 4 100 1000 mA to/from 2000mA 5,6 All 200 µs 4 5 Recovery time step transient load Changes 6,7 TT LOAD 0 mA to/from 1000 mA 5,6 All 10 ms 04 05 Output response to transient step line changes VO TLINE Input step 18 V to/from 40 V dc, I OUT = 2000mA 4, 8 4,5,6 06 -1000 +1000 mV pk 04 05 Recovery time transient step line changes TT LINE Input step 18 V to/from 40Vdc I OUT = 2000mA 4, 7, 8 4,5,6 06 500 µs Turn on overshoot VTon OS I OUT = 0 and 2000mA 4,5,6 All 750 mV pk Turn on delay Ton D I OUT = 0 and 2000mA 9 4,5,6 All 12 ms Load fault recovery 4,9 Tr LF 4,5,6 All 12 ms Weight 38 grams |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |