Back Button PLMX2820RTCT Datasheet HTML 17Page - Texas Instruments PLMX2820RTCT Datasheet HTML 18Page - Texas Instruments PLMX2820RTCT Datasheet HTML 19Page - Texas Instruments PLMX2820RTCT Datasheet HTML 20Page - Texas Instruments PLMX2820RTCT Datasheet HTML 21Page - Texas Instruments PLMX2820RTCT Datasheet HTML 22Page - Texas Instruments PLMX2820RTCT Datasheet HTML 23Page - Texas Instruments PLMX2820RTCT Datasheet HTML 24Page - Texas Instruments PLMX2820RTCT Datasheet HTML 25Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 40 page
background image
÷2,4,8
SYSREF_DIV_PRE
÷4,6,8,.. 4098
SYSREF_DIV
Re-clocking
Circuit
÷2
÷2
SROUT_P
VCCBUF
SROUT_N
Programmable
Delay
SRREQ_P
SRREQ_N
JESD_DACx_CTRL
SYSREF_PULSE_CNT
From VCO
SysRef Pulse
Generator
SYSREF_REPEAT
SYSREF_PULSE
21
LMX2820
www.ti.com
SNAS783 – JUNE 2020
Product Folder Links: LMX2820
Submit Documentation Feedback
Copyright © 2020, Texas Instruments Incorporated
spurs. If used with a non-zero numerator, it can either help or hurt spurs and this effect can be simulated with
the TI PLLatinum Sim tool.
7.3.12.2.2
Static vs. Dynamic Phase Adjust
The programming of the MASH_SEED word is cumulative. By that it means that the programmed value is added
to the current value. Whenever the MASH_RST_N bit or the VCO is re-calibrated, the current value is set to
MASH_SEED. Static phase adjust would involve setting the MASH_SEED word to the desired value and toggling
the MASH_RST_N bit to force this value. Dynamic phase adjust involves setting MASH_SEED to a smaller value
and repetitively program the MASH_SEED word to add to the cumulative value for MASH_SEED.
7.3.12.2.3
Fine Adjustments to Phase Adjust
Phase SYNC refers to the process of getting the same phase relationship for every power-up cycle and each
time assuming that a given programming procedure is followed. However, there are some adjustments that can
be made to get the most accurate results. As for the consistency of the phase SYNC, the only source of variation
could be if the VCO calibration chooses a different VCO core and capacitor, which can introduce a bimodal
distribution with about 10 ps of variation. If this 10 ps is not desirable, then it can be eliminated by either using
the instant calibration based VCO calibration or Full assist VCO calibration.
The delay through the device varies from part to part and can be on the order of 60 ps. This part to part variation
can be calibrated out with the MASH_SEED. The variation in delay through the device also changes on the order
of +2.5 ps/°C, but devices on the same board likely have similar temperatures, so this will somewhat track. In
summary, the device can be made to have consistent delay through the part and there are means to adjust out
any remaining errors with the MASH_SEED. This tends only to be an issue at higher output frequencies when
the period is shorter.
7.3.13 SYSREF
The LMX2820 can generate a SYSREF output signal that is synchronized to fOUT with a programmable delay.
This output can be a single pulse, series of pulses, or a continuous stream of pulses. To use the SYSREF
capability, the PLL must first be placed in SYNC mode with PHASE_SYNC_EN = 1.
Figure 12. SYSREF Functional Diagram
The SYSREF feature uses SYSREF_DIV_PRE divider to generate fINTERPOLATOR. This frequency is used for
reclocking of the rising and falling edges at the SRREQ pin. In master mode, the fINTERPOLATOR is further divided
by 2 × SYSREF_DIV to generate finite series or continuous stream of pulses.
7.3.14 Fast VCO Calibration
The time that it takes the VCO to calibrate can be reduced. Table 6 shows the general methods of VCO
calibration:
Table 6. Types of VCO Calibration
CALIBRATION TYPE DESCRIPTION
No Assist
User does nothing to improve VCO calibration speed, but the user-specified VCO_SEL, VCO_DACISET and
VCO_CAPCTRL values do affect the starting point of VCO calibration.
Partial Assist
Upon every frequency change, before the FCAL_EN bit is checked, the user provides the initial starting point for the
VCO core (VCO_SEL), band (VCO_CAPCTRL), and amplitude (VCO_DACISET) based on values specified in the
datasheet.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


Arkusz danych Pobierz

Go To PDF Page


Link URL



Czy Alldatasheet okazała się pomocna?  [ DONATE ] 

O Alldatasheet   |   Reklama   |   Kontakt   |   Polityka prywatności   |   Link do karty katalogowej    |   Linki   |   Lista producentów
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com