| Zakładka z wyszukiwarką danych komponentów |
|
MAS3559F Arkusz danych(PDF) 36 Page - Micronas |
|
|
|||||||||||||||||||||||||||||
MAS3559F Arkusz danych(HTML) 36 Page - Micronas |
|
36 / 92 page ![]() MAS 35x9F DATA SHEET 36 June 30, 2004; 6251-505-1DS Micronas D0:34d Operation Mode Selection (reset = 0 hex) G.729 The register is used to switch between basic G.729 operation modes. bit[19:7] Reserved, set to 0 bit[6] Page headers 0 enable 1 disable If the page headers bit is 0, a header frame is transfered before each page of 50 data frames. If the header bit is 1, all the frames are G.729 data frames. Please (see Section 3.3.8. on page 44). bit[5:4] Decoding speed 00 8 kHz (normal) 01 6 kHz (slow) 10 12 kHz (fast) 11 not allowed The recording (encoding) is always done with a sampling rate of 8 kHz. During decoding this control can be used to speed up or slow down the playback. bit[3] Reserved, set to 0 bit[2] Pause encoder/decoder 0 normal operation 1 pause If the pause bit is set, the processing continues until the current page is fin- ished and then en-/decoding is paused. The pause mode lasts until the pause bit is cleared again or the mode is set to 0. bit[1:0] Mode 00 idle 01 decode 10 not allowed 11 encode To switch to encoder operation mode, UserControl has to be set to 3 hex. Then 50 frames are encoded and sent via the PIO interface. This is repeated until the UserControl register is changed. If the transmission of headers is enabled, each page of 50 frames is preceeded by a header frame as shown in Fig. 3–4 on page 44. To switch to decoder operation mode, UserControl has to be set to 1 hex. For decoding with slow speed, UserControl must be 11hex, for decoding with fast speed it must be 21hex. Then the decoder is requesting several frames via the PIO interface to fill its internal buffer. If enough data is available, 50 frames are decoded. This is repeated until the UserControl register is changed. If the transmission of headers is enabled, a header frame has to be sent before each page of 50 frames (see Fig. 3–4 on page 44). To switch off the encoder or decoder, UserControl has to be set to 0hex. Then the encoding/decoding and sending/receiving of frames continues until the end of the current page and the operation mode is set to stop. UserControl Table 3–9: D0 control memory cells, continued Memory Address (hex) Function Name |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |