MODEL: KS2V2
KS2V2 SPECIFICATIONS
ES-3608 Rev.10 Page 3/4
https://www.m-system.co.jp/
(input to SET1 or SET2 to power)
500 V AC @1 minute (SET1 to SET2)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II (power)
Measurement Category II (output)
Pollution Degree 2
Input to output to power: Basic insulation (300 V)
RoHS Directive
EXTERNAL VIEW
A. Measured Value (PV) /
Alarm SET1 Display
B. Measured Value (PV)
Indicator LED
D. SELECT Key
C. Alarm SET2 / Parameter Display
J. Alarm SET2 Indicator LED
H. Alarm SET1 Indicator LED
G. Power Indicator LED
F. DOWN Key
E. UP Key
B
Measured Value (PV) Indicator LED
A
Measured Value (PV) / Alarm SET1 Display
C
Alarm SET2 / Parameter Display
D
SELECT Key
E
UP Key
F
DOWN Key
G
Power Indicator LED
H
Alarm SET1 Indicator LED
J
Alarm SET2 Indicator LED
Ref.
Component Name
LED turns on when the Alarm SET2 is in tripped conditions.
Displaying either of Measured Value (PV) or Alarm Setpoint Value (SET1)
LED turns on when the Measured Value (PV) is displayed.
Displaying either of Alarm Setpoint Value (SET2) or parameter type code.
Used for confirming current setpoints and switching between parameter blocks.
Pressing the key increases display values.
They change continuously when it is kept pressed.
Pressing the key decreases display values.
They change continuously when it is kept pressed.
LED turns on while the power is turned on.
LED turns on when the Alarm SET1 is in tripped conditions.
Function



Html Pages

1 2 3 4


Arkusz danych Pobierz

Go To PDF Page


Link URL



Czy Alldatasheet okazała się pomocna?  [ DONATE ] 

O Alldatasheet   |   Reklama   |   Kontakt   |   Polityka prywatności   |   Link do karty katalogowej    |   Linki   |   Lista producentów
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com