Zakładka z wyszukiwarką danych komponentów
  Polish  ▼
ALLDATASHEET.PL

X  

MMD-2060H Arkusz danych(PDF) 5 Page - Marki Microwave

Numer części MMD-2060H
Szczegółowy opis  GaAs MMIC Millimeter Wave Doubler
PDF  10 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Producent  MARKIMICROWAVE [Marki Microwave]
Strona internetowa  https://www.markimicrowave.com/
Logo MARKIMICROWAVE - Marki Microwave

MMD-2060H Arkusz danych(HTML) 5 Page - Marki Microwave

  MMD-2060H Datasheet HTML 1Page - Marki Microwave MMD-2060H Datasheet HTML 2Page - Marki Microwave MMD-2060H Datasheet HTML 3Page - Marki Microwave MMD-2060H Datasheet HTML 4Page - Marki Microwave MMD-2060H Datasheet HTML 5Page - Marki Microwave MMD-2060H Datasheet HTML 6Page - Marki Microwave MMD-2060H Datasheet HTML 7Page - Marki Microwave MMD-2060H Datasheet HTML 8Page - Marki Microwave MMD-2060H Datasheet HTML 9Page - Marki Microwave Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 10 page
background image
www.markimicrowave.com
MMD-2060H
Copyright © 2018 Marki Microwave, Inc.
P a g e 5 | R e v . A
3.5 Electrical Specifications
The electrical specifications apply at TA=+25°C in a 50Ω system. Typical data shown is
for the connectorized U package doubler used in the forward direction with a +11 dBm
sine wave input.
Min and Max limits apply only to our connectorized units and are guaranteed at TA=+25°C. RF testing of our die is performed on a sample
basis to verify conformance to datasheet guaranteed specifications.
Parameter
Test Conditions
Min
Typical Max
Units
Input (Port 1) Frequency Range
10
30
GHz
Output (Port 2) Frequency
Range
20
60
Input Power
+10
+15
dBm
2F Conversion Loss (CL)
Input = 10 - 30 GHz
Output = 20 - 60 GHz
10.5
13
dB
Suppression2,3
1F
Input = 10 - 30 GHz
Output = 10 - 30 GHz
38
dBc
3F
Input = 10 – 20 GHz
Output = 30 - 60 GHz
39.5
4F
Input = 10 – 15 GHz
Output = 40 - 60 GHz
12.5
Isolations4
1F
Input = 10 – 30 GHz
Output = 10 - 30 GHz
49.7
dB
3F
Input = 10 – 20 GHz
Output = 30 – 60 GHz
50
4F
Input = 10 – 15 GHz
Output = 40 - 60 GHz
22.5
2 Suppressions and isolations measured with an input source with >60dBc (relative to fundamental
input) harmonic suppression
3 Suppression is defined as the harmonic power relative to the 2F doubled output power
4 Isolation is defined as the harmonic power relative to the 1F fundamental input power.



Html Pages

1 2 3 4 5 6 7 8 9 10


Arkusz danych Pobierz

Go To PDF Page


Link URL



Czy Alldatasheet okazała się pomocna?  [ DONATE ] 

O Alldatasheet   |   Reklama   |   Kontakt   |   Polityka prywatności   |   Link do karty katalogowej    |   Linki   |   Lista producentów
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com