| Zakładka z wyszukiwarką danych komponentów |
|
73VR3100-E-R Arkusz danych(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
73VR3100-E-R Arkusz danych(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 14 page ![]() MODEL: 73VR3100 73VR3100 SPECIFICATIONS ES-7397 Rev.30 Page 3/14 http://www.m-system.co.jp/ AV8: DC voltage input alarm, 8 ch. AT4: Thermocouple input alarm, 4 ch. AR4: RTD input alarm, 4 ch. AD4: 4 – 20 mA input alarm w/exc., 4 ch. Blank Filler Module DM: Blank filler module (Communication mode suffix code is not applicable to the blank filler module.) [2] COMMUNICATION MODE S: Single W: Dual (Select the /W code when a Network Module is used.) ● I/O MODULE WITH CONNECTOR TERMINAL R3Y–[1][2] [1] MODEL Analog Input(FCN connector) SS8: DC current input, 8 ch. SS8N: DC current input, 8 ch., non-isolated SV8: DC voltage input, 8 ch. SV8N: DC voltage input, 8 ch., non-isolated SV16N: DC voltage input, 16 ch., non-isolated RS8: RTD input, 8 ch. MS8: Potentiometer input, 8 ch. Pulse Input(FCN connector) PA16: Totalized pulse input, 16 ch. Discrete Input(FCN connector) DA16: Optical isolation discrete input, 16 ch. (13 V DC) Discrete Output(FCN connector) DC16: Realy output 16 ch. (Limited to two discrete output modules at the maximum.) [2] COMMUNICATION MODE S: Single W: Dual (Select the /W code when a Network Module is used.) ● R3-CTxA, R3-CTxB, R3-WT4x, R3-WTU In order to use models R3-CTxA, R3-CTxB, R3-WT4x and R3- WTU, the data range must be set up with the R3 Configurator Software (model: R3CON). This change of setting may lower the resolution of recorded data for certain input ranges. The R3CON Configurator Software is available for downloading at M-System’s web site. A special cable is required to connect the R3 modules to a PC. The Clamp-on Current Sensors, NOT included in the product package of the R3 modules, must be purchased separately. Please refer to data sheet for the respective models (CLSA or CLSB or CLSE). The CLSA is used for the R3-CT4A and R3-CT8A and R3- WT4A. The CLSB is used for the R3-CT4B and R3-CT8B and R3- WT4B. The CLSB-R5 is used for the R3-CT4C and R3-CT8C. The CLSE is used for the R3-WTU. ● R3-PA2 The R3-PA2 can handle a data range of -1 000 000 000 to 1 000 000 000 to represent encoder’s positions, while the 73VR3100 can handle only from 0 to 1 000 000 000. Be sure that the input to the R3-PA2 remains within this range. The R3-PA2’s alarm output cannot be triggered from the 73VR3100. ● R3-DAC16A Mode setting is aveilable only for continuous output mode. |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |