Zakładka z wyszukiwarką danych komponentów
  Polish  ▼
ALLDATASHEET.PL

X  

PLL600-27BSC-R Arkusz danych(PDF) 2 Page - PhaseLink Corporation

Numer części PLL600-27BSC-R
Szczegółowy opis  Ultra Low Current XO 10 MHz to 52 MHz
PDF  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Producent  PLL [PhaseLink Corporation]
Strona internetowa  http://www.phaselink.com
Logo PLL - PhaseLink Corporation

PLL600-27BSC-R Arkusz danych(HTML) 2 Page - PhaseLink Corporation

  PLL600-27BSC-R Datasheet HTML 1Page - PhaseLink Corporation PLL600-27BSC-R Datasheet HTML 2Page - PhaseLink Corporation PLL600-27BSC-R Datasheet HTML 3Page - PhaseLink Corporation PLL600-27BSC-R Datasheet HTML 4Page - PhaseLink Corporation PLL600-27BSC-R Datasheet HTML 5Page - PhaseLink Corporation  
Zoom Inzoom in Zoom Outzoom out
 2 / 5 page
background image
Preliminary
PLL600-27B
Ultra Low Current XO 10 MHz to 52 MHz
47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 11/03/05 Page 2
^ Internal Pull-up, default value is ‘1’ when not connected.
PACKAGE PIN DESCRIPTION
Pin No.
Pad
Type
Description
Name
SOIC-8
SOT-6
No.
X (
µm)
Y (
µm)
XIN/FIN
1
3
1
94.18
768.60
I
Crystal input or reference clock input pin.
OE
2
1
2
94.16
605.03
I
Output Enable input. See Table on page 1.
DNC
3
-
4
94.18
331.76
-
Do Not Connect.
GND
4
2
3
94.19
140.38
P
Ground connection.
CLK
5
6
5
715.31
203.87
O
Output clock.
VDD
6
5
6
715.31
455.73
P
Power supply connection.
DNC
7
-
7
715.47
626.72
-
Do Not Connect.
XOUT
8
4
8
476.91
888.88
O
Crystal output.
OE has internal pull-up resistor, so the default value is ‘1’ when not connected.
ELECTRICAL SPECIFICATIONS
1. Absolute Maximum Ratings
PARAMETERS
SYMBOL
MIN.
MAX.
UNITS
Supply Voltage
VDD
4.6
V
Input Voltage, dc
VI
-0.5
VDD+0.5
V
Output Voltage, dc
VO
-0.5
VDD+0.5
V
Storage Temperature
TS
-65
150
°C
Ambient Operating Temperature*
TA
-40
85
°C
Junction Temperature
TJ
125
°C
Lead Temperature (soldering, 10s)
260
°C
ESD Protection, Human Body Model
2
kV
Exposure of the device under conditions beyond the limits specified by Maximum Ratings for extended periods may cause permanent damage to the
device and affect product reliability. These conditions represent a stress rating only, and functional operations of the device at these or any other
conditions above the operational limits noted in this specification is not implied.
* Note: Operating Temperature is guaranteed by design for all parts (COMMERCIAL and INDUSTRIAL), but tested for COMMERCIAL grade only.



Html Pages

1 2 3 4 5


Arkusz danych Pobierz

Go To PDF Page


Link URL



Czy Alldatasheet okazała się pomocna?  [ DONATE ] 

O Alldatasheet   |   Reklama   |   Kontakt   |   Polityka prywatności   |   Link do karty katalogowej    |   Linki   |   Lista producentów
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com