14 / 38 page ![]() Table 13. Safety limits Symbol Parameter Test conditions Value Unit Input safety, Logic side TSI Safety temperature of Logic side - 150 °C PSI Safety power of Logic side(1) VDD ≤ 6.0 V, VLOGIC(x) ≤ 6.0 V, ILOGIC(x) ≤ 10 mA, TJ ≤ TSI 0.9 W Output safety, Process side TSO Safety temperature of Process side - 150 °C PSO Safety power of Process side(1) VCC ≤ 36 V, IOUT(x) ≤ 1.5 A, TJ ≤ TSO 5 W 1. Respecting the above limits prevents potential damage to the isolation barrier upon failure on logic or process side circuitry. The user should apply these values to protect the IC and ensure the safety of the embedded isolation barrier. LOGIC(x) stands for any pin on the logic side; OUT(x) stands for any of the 8 output pins on the process side. ISO808, ISO808-1 Electrical characteristics DS14169 - Rev 1 page 14/38 |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|