| Zakładka z wyszukiwarką danych komponentów |
|
THDF Arkusz danych(PDF) 1 Page - Greystone Energy Systems Inc. |
|
|
|||||||||||||||||||||||||||||
THDF Arkusz danych(HTML) 1 Page - Greystone Energy Systems Inc. |
|
1 / 2 page ![]() GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM FLEXIBLE CABLE DUCT AVERAGE HIGH LIMIT THERMOSTAT THDF SERIES CABLE GLAND FITTING THREAD ADAPTER 1/2” NPT TO M16 ACCESSORIES - INCLUDED WITH F ENCLOSURE OPTION PRODUCT DESCRIPTION The flexible, multi-point duct averaging high limit thermostat incorporates several precision thermistor temperature sensors and provides a Form C relay output (NO/NC) with an adjustable setpoint. The probe is FT-6 plenum rated cable and is available in various lengths (see ordering chart). All probes are constructed to provide excellent heat transfer and a fast response. A Polycarbonate enclosure with a hinged and gasketed cover is included for ease of installation. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The flex-duct average probes are installed through a hole in the side of the duct to monitor an average temperature within the duct. Select a probe length that allows for criss-crossing the duct multiple times. Install the probes in a straight section of duct at a suitable distance downstream from any heating, cooling, or humidification devices. The cable probe needs to be fastened onto hangers using tube clamps or wire ties and should be secured every 100 cm or 3’ maximum to prevent movement of the wire and prevent wear. If sensor is to be used in high velocity or vibration environment use of rigid style duct probe is recommended. The enclosure provides mounting tabs for ease of installation. POWER SUPPLY 12 to 28 Vac/dc SENSOR ACCURACY ±0.2°C, 0 to 70°C (±0.36°F, 32 to 158°F) PROBE SENSING RANGE -20 to 60°C (-4 to 140°F) WIRE MATERIAL FT-6 plenum rated cable, 22 AWG STANDARD LENGTHS 1800mm, 3600mm, 6100mm, 7300mm (6’, 12’, 20’, 24’) CONSUMPTION 50 mA max RELAY CONTACTS SPDT, Form C contacts (N.O. and N.C.) 5 Amps @ 30 Vdc/250 Vac resistive 1.5 Amps @ 30 Vdc/250 vac inductive RELAY ACTION Activates on temperature rise SETPOINT OPERATION Single-turn knob-pot on PCB ADJUSTABLE SETPOINT 38 to 60°C (100 to 140°F) TEMPERATURE DIFFERENTIAL Low: 1.1°C (2°F) Mid: 2.8°C (5°F) High: 5.6°C (10°F) Jumper selectable TEMPERATURE SENSOR 10,000Ω curve matched precision thermistor OPERATING CONDITIONS -10 to 50°C (14 to 122°F), 5 to 95 %RH, non-condensing STORAGE CONDITIONS -30 to 70°C (-22 to 158°F), 5 to 95 %RH, non-condensing WIRING CONNECTIONS Screw terminal block (14 to 22 AWG) ENCLOSURE B: Grey polycarbonate UL94-V0, IP65 (NEMA 4X) F: Same as B with thread adapter (1/2” NPT to M16) and cable gland fitting COUNTRY OF ORIGIN Canada SPECIFICATIONS 112.5 mm 4.43" 99.7 mm 3.93" Foam Gasket Various Probe Lengths See Specifications 304 Series S/S Probe FT-6 Plenum Rated Cable 116.5 mm 4.58” 0.5" NPT 53.7 mm 2.11" |
Podobny numer części - THDF |
|
Podobny opis - THDF |
|
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |