| Zakładka z wyszukiwarką danych komponentów |
|
AS73211 Arkusz danych(PDF) 50 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
AS73211 Arkusz danych(HTML) 50 Page - OSRAM GmbH |
|
50 / 66 page ![]() Document Feedback AS73211 Register Description Datasheet • PUBLIC DS000556 • v3-01 • 2018-Feb-07 65 │ 49 Figure 49: Configuration Register 2 (CREG2) – Address 7h CREG2 NAME VALUE [b] CONFIGURATION bit 7 Reserved (1) bit 6 EN_TM 0 In combination with SYND mode the internal measurement of the conversion time is disabled and no temperature measurement takes place. 1 (2) Internal measurement of the externally defined conversion time via SYN pulse in SYND mode is enabled (OUTCONV results are generated as well as temperature values for output register TEMP). bit 5 to 4 Reserved (1) bit 3 EN_DIV 0 (2) Digital divider of the measurement result registers is disabled 1 Digital divider of the measurement result registers is enabled (might be needed @ CREG1:TIME > 6 dec) bit 2 to 0 DIV Value of the divider (21+DIV[dec]) 000 (2) 21 001 22 010 23 011 24 100 25 101 26 110 27 111 28 (1) The default value after power- on reset and software reset is ,0‘ as well as the recommended write value. (2) Default value after power-on reset and software reset. In SYND mode, the conversion time is externally controlled via pin SYN. In that case the bit CREG2:EN_TM enables the counting of internal clocks within the external given conversion time as well as the access to the output register OUTCONV, which contains the counting result. It is possible to count a number of clocks up to 24 bits. In case of this function is not used in SYND mode (equal to CREG2:EN_TM = ,0 ‘) no result for temperature measurement is generated. The values for output register TEMP are not valid. The bit CREG2:EN_DIV enables the internal prescaler, which could be interesting for conversion times more than 16 bits (CREG1:TIME ≥ 0111b) and in case of SYND mode is used. The value of CREG2:DIV is only valid with CREG2:EN_DIV = ,1 ‘. Then the measurement range is extended while the resolution of the 16-bit register results is reduced at the same time (see Divider). Thus it is also possible to generate complete measurement results for conversion times from 217 to 224 system clocks (CREG1:TIME). If the chosen value of the prescaler is too small, a counter overflow could occur, which is shown by the bit STATUS:MRESOF of the result register bank. |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |