2 / 5 page ![]() NET2 AC-DC Series Data Sheet APR 19, 2005 revised to JUN 28, 2006 Page 2 of 5 www.power-one.com Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC input. 47 63 Hz Hold-up Time After last AC line peak at 400 watts. 20 ms Input Current 85 VAC at full rated load. 7.0 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 220 VAC, one cycle, 25°C. 35 APK Power Factor Per EN61000-3-2 (Over the entire input range and above 60W load). 0.95 W/VA Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Efficiency Full Rated Load, 115 VAC. Varies with distribution of loads among outputs. 85 % Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Charts Output Power With 460 LFM forced-air cooling (25 CFM through the power supply opening), V1+V2+V3+V4+V5: 400 Watts V1+V2 or V3+V4: 200 Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 3.5 % Regulation Varies by output. Regulation includes: line changes over the specified See Model Selection Charts input range and changes in load between 0% and 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50% load change in V1/V4/V5: 1 ms the load range of 10 to 100%; 3.5% or 100mV deviation, whichever is greater. V2/V3 0.5 Turn-on Delay Time required for initial output voltage stabilization. 1.5 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 ms Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Overvoltage Protection Overvoltage protection on all outputs except V5. 120 140 % Unit latches off when overvoltage is detected. AC input must be recycled to reset. V5 is protected by a 6.2V ±5%, 2W Zener diode. Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. All outputs are individually current limited. Overtemperature Protection Power supply shuts down due to excessive internal overtemperature at the output converter’s primary switching transistors. Power supply resets automatically upon removal of the overtemperature cause. Output Good TTL-compatible global Output Good signal. The signal is active when any of the V1-V4 outputs drop >14% below nominal. Source impedance is 1k . Input Power Fail Warning Open collector signal. Time before regulation dropout due to loss of input 5ms power. May be used as independent PSOK signal in redundant applications. Current Share Available on all outputs except V5. Accuracy of shared current with up 10 % to two parallel units. Single wire current share is provided. For paralleling more than two units, consult factory. Remote Sense Available on all outputs except V5. Total voltage compensation for cable losses with 500 mV respect to the main output. |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |