| Zakładka z wyszukiwarką danych komponentów |
|
ISO7340C Arkusz danych(PDF) 3 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
ISO7340C Arkusz danych(HTML) 3 Page - Texas Instruments |
|
3 / 38 page ![]() 3 ISO7340C, ISO7340FC, ISO7341C, ISO7341FC, ISO7342C, ISO7342FC www.ti.com SLLSEI6G – SEPTEMBER 2014 – REVISED JANUARY 2017 Product Folder Links: ISO7340C ISO7340FC ISO7341C ISO7341FC ISO7342C ISO7342FC Submit Documentation Feedback Copyright © 2014–2017, Texas Instruments Incorporated Changes from Revision C (December 2014) to Revision D Page • Changed the DIN V VDE 0884-10 number in the Features Safety and Regulatory Approvals: ............................................ 1 • Added "(Approval Pending)" to the CSA Component Acceptance list item in the Features .................................................. 1 • Deleted "All Agencies Approvals Planned" from the Features Safety and Regulatory Approvals: ........................................ 1 • Changed the Simplified Schematic: VCC1 To VCCI, VCC2 to VCCO and GND1 to GNDI, GND2 to GNDO. Added Notes 1 and 2.................................................................................................................................................................................... 1 • Added Note: "Maximum voltage must not exceed 6 V:" to Absolute Maximum Ratings........................................................ 7 • Added "DT1" to the Minimum internal gap in Insulation and Safety-Related Specifications for DW-16 Package ................. 9 • Changed VIORM "Maximum repetitive peak voltage" To: "Maximum repetitive peak isolation voltage per DIN V VDE V 0884-10" in Insulation Characteristics ................................................................................................................................... 9 • Changed VIOTM From: "DIN V VDE 0884-10 " To: "DIN V VDE V 0884-10" in Insulation Characteristics ............................ 9 • Changed VIOSM "Maximum surge voltage per DIN V VDE 0884-10 " To: "Maximum surge isolation voltage per DIN V VDE V 0884-100" in Insulation Characteristics ..................................................................................................................... 9 • Changed VIOSM Test Conditions in Insulation Characteristics ............................................................................................... 9 • Changed VPR From: "DIN V VDE 0884-10 " To: "DIN V VDE V 0884-10" in Insulation Characteristics ............................... 9 • Changed RS Test Conditions in Insulation and Safety-Related Specifications for DW-16 Package From: TS To: TS = 150°C ..................................................................................................................................................................................... 9 • Changed the Safety-Related Certifications table ................................................................................................................ 10 • Changed title From: " IEC Safety Limiting Values" To: Safety Limiting Values ................................................................... 10 • Changed MIN value for VOH in the Electrical Characteristics From: VCCx - 0.5 To: VCCO - 0.5 ............................................ 11 • Changed VCCx To VCCO in Note 1 of the Electrical Characteristics....................................................................................... 11 • Changed MIN value for VOH in the Electrical Characteristics From: VCCx - 0.5 To: VCCO - 0.5 ............................................ 12 • Changed VCCx To VCCO in Note 1 of the Electrical Characteristics....................................................................................... 12 • Changed Function Table Header information From: INPUT-SIDE VCC To: VCCI and OUTPUT-SIDE VCC To: VCCO ......... 21 • Changed Device I/O Schematics From: VCC To: VCCI on the inputs and VCCO on Output and Enabled............................... 21 • Moved Typical ISO7340x Circuit Hook-up to Typical ISO7342x-Q1 Circuit Hook-up from the Design Requirements section to the Detailed Design Procedure section................................................................................................................ 23 Changes from Revision B (November 2014) to Revision C Page • Changed the Handling Ratings table to ESD Ratings ............................................................................................................ 7 • Changed Minimum internal gap MIN value in Insulation and Safety-Related Specifications for DW-16 Package From: 0.014 mm To: 13.5 µm................................................................................................................................................. 9 • Changed Minimum internal gap MIN value in Insulation and Safety-Related Specifications for DW-16 Package From: 13.5 µm To: 13 µm....................................................................................................................................................... 9 • Delete text "per DIN V VDE 0884-10" from VIORM in the table in section Insulation Characteristics ..................................... 9 • Changed From: VPEAK To VPK in the UNIT column of the table in section Insulation Characteristics .................................... 9 • Added VIOSM to the table in section Insulation Characteristics .............................................................................................. 9 • Changed the table in Safety-Related Certifications section - removed text "Certified according to", "Approved under", "Recognized under", changed "pending" To: "planned" .......................................................................................... 10 • Changed Maximum Repetitive Peak Voltage, 1414 VPK To: Maximum surge voltage , 6000 VPK in the VDE column of the table in section Safety-Related Certifications............................................................................................................. 10 • Changed the ICC2, Supply current, DC to 1 Mbps TYP value From: 3 To 3.2 mA .............................................................. 11 • Changed the ICC2, Supply current, 10 Mbps TYP value From: 5.1 To 5.6 mA .................................................................... 11 • Changed the ICC2, Supply current, 25 Mbps TYP value From: 8.6 To 9.3 mA .................................................................... 11 • Changed the ICC1, Supply current, 10 Mbps TYP value From: 0.8 To 0.9 mA .................................................................... 12 • Changed the ICC2, Supply current, 10 Mbps TYP value From: 0.3.6 To 3.9 mA ................................................................. 12 • Changed the ICC2, Supply current, 25 Mbps TYP value From: 5.9 To 6.3 mA .................................................................... 12 |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |