Back Button HCC4029BF Datasheet HTML 4Page - STMicroelectronics HCC4029BF Datasheet HTML 5Page - STMicroelectronics HCC4029BF Datasheet HTML 6Page - STMicroelectronics HCC4029BF Datasheet HTML 7Page - STMicroelectronics HCC4029BF Datasheet HTML 8Page - STMicroelectronics HCC4029BF Datasheet HTML 9Page - STMicroelectronics HCC4029BF Datasheet HTML 10Page - STMicroelectronics HCC4029BF Datasheet HTML 11Page - STMicroelectronics HCC4029BF Datasheet HTML 12Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 13 page
background image
APPLICATIONS
Conversion of Clock up, Clock Down Input Sig-
nals to Clock and Up/Down Inputs Signals.
Cascading Counter Packages.
The HCC/HCF4029B CLOCK and UP/DOWN in-
puts are used directly in most applications. In appli-
cations where CLOCK UP and CLOCK DOWN
inputs
are
provided,
conversion
to
the
HCC/HCF4029B CLOCK and UP/DOWN inputs
can easily be realized by use of the circuit.
HCC/HCF4029B changes count on positive transi-
tions of CLOCK UP or CLOCK DOWN inputs. For
the gate configuration shown below, when counting
up the CLOCK DOWN input must be maintained
high and conversely when counting down the
CLOCK UP input must be maintained high.
*
CARRY-OUT lines at the 2nd, 3rd, et., stages may have a negative-going glitch pulse resulting from differential delays of different
HCC/HCF4029B IC’s. These negative-going glitches do not affect proper HCC/HCF4029B operation. However, if the CARRY-OUT signals
are used to trigger other edge-sensitive logic devices, such as FF’s or counters, the CARRY-OUT signals should be gated with the clock signal
using a 2-input NOR gate such as HCC/HCF4001B.
Ripple Clocking Mode : The Up/Down control can be changed at any count. The only restriction on changing the Up/Down control is that the
clock input to the first counting stage must be high.
HCC/HCF4029B
8/13



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


Arkusz danych Pobierz

Go To PDF Page


Link URL



Czy Alldatasheet okazała się pomocna?  [ DONATE ] 

O Alldatasheet   |   Reklama   |   Kontakt   |   Polityka prywatności   |   Link do karty katalogowej    |   Linki   |   Lista producentów
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com