20 / 26 page ![]() Enable greater than BCR1[0] Default: 0 This control bit determines whether the comparator in the statistics monitor behaves as a ‘greater than’, or as a ‘less than’ comparator. The signal from this comparator is used to drive the Over / Undershoot Counter and the Max / Min Register. A one at this location selects ‘greater than’. BCR1[1-0] Statistics monitor mode 0 0 Min. register * 0 1 Max. register 1 0 Undershoot counter 1 1 Overshoot counter 10.6 Backend control register 2 (BCR2) Reserved BCR2[7] Default: 0 This location is reserved. The user should write zero to this location to maintain compatibility with future products. The value read from this location will be zero. Pass LUT data to least significant output BCR2[6] Default: 0 This bit controls the output multiplexer. If this bit is set to one, the selected byte from the LUT is output on the least significant byte (bits 7 to 0) of the Cascade Output pins. Pass LUT data to most significant output BCR2[5] Default: 0 This bit controls the output multiplexer. If this bit is set to one, the selected byte from the LUT is output on the most significant byte (bits 21 to 14) of the Cascade Output pins. Look up prescaler BCR2[4-0] Default: 00000 The contents of these five bits control the amount of (arithmetic) right shift applied to the data, by the Look up Prescaler. Writing a numerical value be- tween 0 and 16 (binary 10000) into these bits, will cause the data to be right-shifted by a correspond- ing number of places. For example, if the bit pattern 00101 is written to these five bit positions, a right shift of 5 places will occur. Writing any value outside the range (0 to 16) will result in undefined behaviour of the look up Prescaler. 10.7 Backend control register 3 (BCR3) Normalizer control BCR3[7-3] Default: 00000 These five bits control the number of places, that the normaliser shifts the data to the right or to the left. This field is interpreted as a twos complement number. A positive number is taken to be a right shift. Any shift in the range -2 (11110) to +14 (01110) is legal. Any other value will cause the number zero to be output from the normaliser. Enable dynamic normalization BCR3[2] Default: 0 If this bit is set to one, the normaliser will be con- trolled by bits 26 to 22 from the output of the look up table, instead of BCR3[7-3]. Feed LUT data to output adder BCR3[1] Default: 0 One of the inputs of the Output Adder can be either supplied by the Look up Table or forced to zero. Setting this control bit to zero selects zero. Setting this control bit to one selects bits 21 to 0 of the Look up Table. Reserved BCR3[0] Default: 0 This location is reserved. The user should write zero to this location to maintain compatibility with future products. The value read from this location will be zero. IMSA110 20/26 |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |