| Zakładka z wyszukiwarką danych komponentów |
|
M48Z128CS Arkusz danych(PDF) 6 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M48Z128CS Arkusz danych(HTML) 6 Page - STMicroelectronics |
|
6 / 17 page ![]() M48Z128, M48Z128Y 6/17 Table 8. Power Down/Up AC Characteristics (TA = 0 to 70 °C) Note: 1. VPFD (max) to VPFD (min) fall time of less than tF may result in deselection/write protection not occurring until 200µs after VCC pass- es VPFD (min). 2. VPFD (min) to VSO fall time of less than tFB may cause corruption of RAM data. Symbol Parameter Min Max Unit tF (1) VPFD (max) to VPFD (min) VCC Fall Time 300 µs tFB (2) VPFD (min) to VSO VCC Fall Time 10 µs tWP Write Protect Time from VCC =VPFD 40 150 µs tR VSO to VPFD (max) VCC Rise Time 0 µs tER E Recovery Time 40 120 ms Figure 6. Power Down/Up Mode AC Waveforms AI01031 VCC E (PER CONTROL INPUT) OUTPUTS DON’T CARE HIGH-Z tF tFB tR tWP tDR VALID VALID (PER CONTROL INPUT) RECOGNIZED RECOGNIZED VPFD (max) VPFD (min) VSO tER |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |