3 / 8 page ![]() Circuit Note CN-0537 Rev. A | Page 3 of 8 The EVAL-CN0537-ALGO algorithm was specifically designed for detecting fire conditions using the ADPD188BI sensor and optimized smoke chamber, as defined by the UL 217 and UL 268 standards. The algorithm itself was tuned and verified through a large data set, EVAL-CN0537-DATA, captured from many ADPD188BI devices across all of the test scenarios defined in Table 1. The tests were performed at certified OSHA approved laboratories specializing in fire and life safety. The EVAL-CN0537-DATA data set includes reference measurements to understand sensor performance and alarm conditions for different smoke sources. An example smoke profile is shown in Figure 3, where the IR and blue sensor measures are compared against the reference smoke obscuration data under the Hamburger and Polyurethane test scenario. Because battery powered devices are a common use case for smoke detectors, the EVAL-CN0537-ALGO was designed and built to minimize the output data required from the ADPD188BI, along with the number of microcontroller computations necessary while still meeting the strict UL 217 and UL 268 standards. For more details on the testing validation, see the test results. Figure 3. Smoke Profile for Burger Polyurethane Test Calculating the Power Transfer Ratio The smoke response of the ADPD188BI is best expressed as a ratio of the received optical power to the transmitted optical power. Referred to as the power transfer ratio (PTR), this parameter is a much more meaningful value than the raw output codes, as it is independent of the actual hardware settings used. Additionally, obscuration level, the standard unit of measurement for smoke detectors, is directly related to the PTR, as shown in Equation 1. PTR = γβ (1) where: PTR is the power transfer ratio in nW/mW. γ is the ADPD188BI scaling factor (0.64 typical for blue light and 0.24 typical for infrared light). β is the obscuration level in ft-1. Figure 4. Blue LED PTR, IR LED PTR, and Obscuration Level For each LED, the PTR can be calculated using Equation 2. _ 11 PD PD LEDx LEDx PK PD LED PI PTR PI R η = = ×× (2) where: PTR is the power transfer ratio of the LED in nW/mW. IPD is the photodetector current in nA. ILEDx_PK is the peak LED current in mA. RPD is the photodetector responsivity in A/W (0.26 typical for blue light and 0.41 typical for infrared light). ηLEDx is the LED efficiency in W/A. Calculating the ILED and IPD The ADPD188BI allows for configuring the peak currents of each LED through a combination of course and fine adjustment registers and a current scale factor. The peak LED current can be calculated using Equation 3 to Equation 6. ILEDx_PK = ILEDx(COURSE) + ILEDx(FINE) + ILEDx(SCALE) (3) ILEDx(COURSE) = 50.3 + 19.8 × ILSEDx_COURSE (4) ILEDx(FINE) = 0.74 + 0.022 × ILEDx_FINE (5) ILEDx(SCALE) = 0.1 + 0.9 × ILEDx_SCALE (6) where: ILEDx_PK is the peak LED current in mA. ILEDx(COURSE) is the LED course current in mA. ILEDx(FINE) is the LED fine current in mA. ILEDx(SCALE) is the LED current scaling in mA. ILEDx_COURSE, ILEDx_FINE, and ILEDx_SCALE are the values for the control registers for each LED. For the integrated blue LED, these can be set in Register Address 0x23 and Register Address 0x25. For the integrated infrared LED, these can be set in Register Address 0x22 and Register Address 0x25. Note that in the ADPD188BI registers, the blue LED is LEDX1 and the infrared LED is LEDX3. 8 –1 1 0 2 3 5 7 4 6 8 –1 1 0 2 3 5 7 4 6 0 1200 1400 1000 800 600 400 200 TIME (Seconds) REFERENCE OBSCURATION IR BLUE OBSCURATION WINDOW 13.5 13.0 12.5 12.0 11.5 11.0 10.5 10.0 9.5 9.0 8.5 8.0 7.5 7.0 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 –0.5 6.5 4.4 4.2 4.0 3.8 3.6 3.4 3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 1.8 –0.2 TIME (PM) END IGNITE 12% ALARM THRESHOLD AT 5% PER FOOT OBSCURATION |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |