| Zakładka z wyszukiwarką danych komponentów |
|
CN-14A-R-C2 Arkusz danych(PDF) 13 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
CN-14A-R-C2 Arkusz danych(HTML) 13 Page - Panasonic Semiconductor |
|
13 / 16 page ![]() 747 DualDisplayDigitalPressureSensorDP-100SERIESVer.2 Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DP-100 DP-M FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS PRECAUTIONS FOR PROPER USE Refer to p.1472 for general precautions. The line to connect with this sensor should be less than 30 m 98.425 ft. Conditions in use for CE conformity The DP-100 series is a CE conformity product complying with EMC Directive. The harmonized standard with regard to immunity that applies to this product is EN 61000-6-2 and the following condition must be met to conform to that standard. • Condition • 14 mm 0.551 in spanner Note: Do not tighten the pressure port by holding the product with the spanner. It may cause the product breakage. Piping If connecting a commercially-available coupling to the pressure port, attach a 12 mm 0.472 in spanner (14 mm 0.551 in spanner for DP-100-E type) to the hexagonal section of the pressure port to secure it, and tighten at a torque of 9.8 N·m or less. If it is tightened using excessive torque, it may damage the coupling or the pressure port. In addition, wrap sealing tape around the coupling when connecting it to prevent leaks. • 12 mm 0.472 in spanner • The tightening torque should be 1 N·m or less when connecting a coupling to the pressure port of MS-DP1-FM. • If connecting a commercially-available joint to the pressure port of the DP-10□-M, hold the main unit in your hand to steady it, and tighten to a torque of 1.0 N·m or less. If it is tightened to an excessive torque, the joint or the main unit may become damaged. • If connecting a commercially-available joint to the pressure port of the MS-DP1-7, tighten to a torque of 9.8 N·m or less. • When connecting the coupling to the pressure port of MS-DP1-FR/FE/FN, hold the pressure port with a 14 mm 0.551 in spanner and make sure that the tightening torque is 9.8 N·m or less. In addition, in order to prevent any leakage, wind a sealing tape on the coupling when connecting. Coupling (Purchase separately.) Pressure port 14 mm 0.551 in spanner Flat attachment • • • Make sure to mount MS-DP1-F□ with the sensor properly. If it is not mounted properly, air leakage may occur. Take care that the excessive mounting and dismounting of this product may cause deterioration of the O-ring. If you touch the O-ring of MS-DP1-F□, or any scratch or dust, etc. is attached to it, air leakage may occur and the sensing performance may deteriorate. Take sufficient care when using and storing MS-DP1-F□. If the mode selection key is pressed and held for 2 seconds in RUN mode, the mode will switch to MENU SETTING mode. If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. • • Others RUN mode MENU SETTING mode Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on. Avoid dust, dirt, and steam. Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. Do not operate the keys with pointed or sharp objects. • • • • • • • • This is the normal operating mode. Comparative output 1 output mode setting Setting item Description Sets the output mode for comparative output 1. Unit switching Pressure unit can be changed. NO / NC switching Response time setting Comparative output 2 output mode setting (standard type only) Sets the output mode for comparative output 2. Display color switching for main display Analog output / external input switching (multi-function type only) Allows the color for the main display to be changed. The colors can be set to ‘red / green’ or ‘green / red’ to correspond to ON / OFF output, or it can be fixed at ‘red’ or ‘green’ all the time. Sets the response time. The response time can be selected from 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms and 5,000 ms. Sets normally open (NO) or normally closed (NC). Allows switching between analog voltage output / analog current output, and auto-reference input / remote zero-adjust-ment input. Setting item Description Threshold value setting Zero-adjustment function Key lock function Peak hold / bottom hold function Stops key operations from being accepted. The threshold values for ON / OFF operation can be changed directly by pressing the increment key (UP) and the decrement key (DOWN). This forces the pressure value display to be reset to zero when the pressure port is open on the atmospheric pressure side. Displays the peak value and bottom value for fluctuating pressure. The peak value appears in the main display, and the bottom value appears in the sub display. |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |