11 / 18 page ![]() 11 J 18 SERIES 18 SERIES PIR movement and presence detectors 10 A Technical data Insulation Dielectric strength between open contacts V AC 1000 (except for type 18.91 TRIAC output) Between supply and contact V AC 1500 (types 18.21…0300, 18.31…0300, 18.41, 1851, 18.61) EMC specifications Type of test Reference standard Electrostatic discharge contact discharge EN 61000-4-2 4 kV air discharge EN 61000-4-2 8 kV Radiated electromagnetic field (80…2000 MHz) EN 61000-4-3 3 V/m Fast transients (burst 5/50 ns, 5 and 100 kHz) on supply terminals EN 61000-4-4 1 kV Voltage pulses on supply terminals (surge 1.2/50 µs) common mode EN 61000-4-5 4 kV (2 kV for 18.91) differential mode EN 61000-4-5 4 kV (2.5 kV for 18.01/11, 1 kV for 18.91) Radiofrequency common mode voltage (0.15…230 MHz) on supply terminals EN 61000-4-6 3 V Voltage dips 70% UN , 40% UN EN 61000-4-11 10 cycles Short interruptions EN 61000-4-11 10 cycles Radiofrequency conducted emissions (0.15…30)MHz EN 55014 class B Radiated emissions (30…1000)MHz EN 55014 class B Terminals 18.01, 18.11, 18.21, 18.31,18.91 18.41, 18.51, 18.51…B300, 18.61, 18.A1 Type Screw terminal Push-in (see pag. 18) Screw torque Nm 0.5 — Max. wire size solid cable stranded cable solid cable stranded cable mm2 1 x 6 / 2 x 4 1 x 4 / 2 x 2.5 2.5 2.5 AWG 1 x 10 / 2 x 12 1 x 12 / 2 x 14 14 14 Wire strip length mm 9 9 8 8 Other data Power lost to the environment without output current W 0.3 with rated output current W 1.4 • Following the initial power-on, and power-on following a power interruption, the detector makes a hardware-software initialisation for approximately 30 seconds. However, the behavior of the output during this 30 seconds will depend on certain circumstances: - If the detector was in the On state before the power interruption, and if the lighting level is (currently) below the pre-set threshold, then the output contact will immediately close when the power is re-applied, for the time delay set by the potentiometer (irrespective of whether movement is being detected). - If the detector was in the Off state before the power interruption, or if the ambient light is currently over the pre-set threshold, then the detector will not switch-on until the end of the initialisation phase (assuming movement is then detected). |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |