33 / 47 page ![]() SRIX4K SRIX4K commands 33/47 9.5 Completion() command Command code = 0Fh On receiving the Completion() command, an SRIX4K in Selected state switches to Deactivated state and stops decoding any new commands. The SRIX4K is then locked in this state until a complete reset (tag out of the field range). A new SRIX4K can thus be accessed through a Select() command without having to remove the previous one from the field. The Completion() command does not generate a response. All SRIX4K devices not in Selected state ignore the Completion() command. Figure 36. Completion request format Request parameters: ● No parameter Figure 37. Completion response format Figure 38. Completion frame exchange between reader and SRIX4K SOF Completion CRCL CRCH EOF AI07679b 0Fh 8 bits 8 bits AI07680 No Response SOF 0Fh CRCL CRCH EOF AI07681 Reader SRIX4K No Response |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|