18 / 62 page ![]() MCP9843/98243 DS22153C-page 18 © 2009 Microchip Technology Inc. 5.1.1 CAPABILITY REGISTER This is a read-only register used to identify the temperature sensor capability. For example, the MCP9843/98243 device is capable of providing temperature at 0.25°C resolution, measuring temperature below and above 0°C, providing ±1°C and ±2°C accuracy over the active and monitor temperature ranges (respectively) and providing user- programmable temperature event boundary trip limits. Register 5-2 describes the Capability register. These functions are described in further detail in the following sections. REGISTER 5-2: CAPABILITY REGISTER (READ-ONLY) → ADDRESS ‘0000 0000’b U-0 U-0 U-0 U-0 U-0 U-0 U-0 U-0 —— — — — — — — bit 15 bit 8 R-1 R-1 R-1 R-0 R-1 R-1 R-1 R-1 SHDN Status tOUT Range VHV Resolution Meas Range Accuracy Temp Alarm bit 7 bit 0 Legend: R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’ -n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown bit 15-8 Unimplemented: Read as ‘0’ bit 7 Event output status during Shutdown (SHDN Status): 0 = Event output remains in previous state. If the output asserts before shutdown command, it remains asserted during shutdown. 1 = Event output de-asserts during shutdown. After shutdown, it takes tCONV to re-assert the Event output (power-up default) bit 6 I2C Bus time-out (tOUT Range): 0 = Bus time-out range is 10 ms to 60 ms 1 = Bus time-out range is 25 ms to 35 ms (power-up default) bit 5 High Voltage Input 0 = Pin A0 does not accept High Voltage 1 = Pin A0 accepts High Voltage for the EEPROM Write Protect feature (power-up default) bit 4-3 Resolution: 00 = 0.5°C 01 = 0.25°C (power up default) 10 = 0.125°C 11 = 0.0625°C These bits reflect the selected resolution (see Section 5.2.4 “Temperature Resolution”) bit 2 Temperature Measurement Range (Meas. Range): 0 =TA = 0 (decimal) for temperature below 0°C 1 = The part can measure temperature below 0°C (power-up default) |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |