| Zakładka z wyszukiwarką danych komponentów |
|
YOS3C Arkusz danych(PDF) 8 Page - GREATECS |
|
|
|||||||||||||||||||||||||||||
YOS3C Arkusz danych(HTML) 8 Page - GREATECS |
|
8 / 11 page ![]() OLED Display Module 96RGBx96 (1.10”) OLED Display YOS3C sales@greatecs.com www.greatecs.com 8 FUNCTION SPECIFICATION 1. Commands Refer to the Technical Manual for the SEPS114A 2. Power Down and Power up Sequence To protect OEL panel and extend the panel life time, the driver IC power up/down routine should include a delay period between high voltage and low voltage power sources during turn on/off. It gives the OEL panel enough time to complete the action of charge and discharge before/after the operation. 2.1. Power up Sequence 1. Power up VDD & VDDIO 2. Send Display off command 3. Initialization 4. Clear Screen 5. Power up VCC_C 6. Delay 100ms (when VCC_C is stable) 7. Send Display on command 2.2. Power down Sequence 1. Send Display off command 2. Power down Vcc_c 3. Delay 100ms (when Vcc_c is reach 0 and panel is completely discharges) 4. Power down V |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |