E5CN-RML-500 Arkusz danych(PDF) 49 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CN-RML-500 Arkusz danych(HTML) 49 Page - Omron Electronics LLC |
|
49 / 72 page ![]() E5AN-H/E5EN-H 49 Alarm Outputs Each alarm can be independently set to one of the following 15 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function). ✽1.With set values 1, 4 and 5, the upper and lower limit values can be set independently for each alarm type, and are expressed as “L” and “H.” ✽2. Set value: 1, Upper- and lower-limit alarm ✽3. Set value: 4, Upper- and lower-limit range ✽4. Set value: 5, Upper- and lower-limit with standby sequence For Upper- and Lower-Limit Alarm Described Above • Case 1 and 2 Always OFF when the upper-limit and lower-limit hysteresis overlaps. • Case 3: Always OFF ✽5. Set value: 5, Upper- and lower-limit with standby sequence Always OFF when the upper-limit and lower-limit hysteresis overlaps. ✽6. Displayed when there is a remote SP input. Set val- ue Alarm type Alarm output operation When X is positive When X is negative 0 Alarm function OFF Output OFF 1 ✽1 Upper- and lower- limit ✽2 2 Upper limit 3 Lower limit 4 ✽1 Upper- and lower- limit range ✽3 5 ✽1 Upper- and lower- limit with standby sequence ✽5 ✽4 6 Upper-limit with standby sequence 7 Lower-limit with standby sequence 8 Absolute-value upper-limit 9 Absolute-value lower-limit 10 Absolute-value upper-limit with standby sequence 11 Absolute-value lower-limit with standby sequence 12 LBA (for alarm 1 only) --- 13 PV change rate alarm --- 14 RSP absolute value upper limit ✽6 15 RSP absolute value lower limit ✽6 ON OFF SP LH SP X ON OFF SP X ON OFF SP X ON OFF SP X ON OFF SP LH ON OFF SP LH ON OFF SP X ON OFF SP X ON OFF SP X ON OFF SP X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF 0 X ON OFF LH H < 0, L > 0 H < L SP Case 1 LH H > 0, L < 0 H > L SP Case 2 L H H < 0, L < 0 SP L H H < 0, L > 0 H ≥ L SP L H H > 0, L < 0 H ≤ L SP Case 3 (Always ON) LH H < 0, L > 0 H < L SP Case 1 LH H > 0, L < 0 H > L SP Case 2 L H H < 0, L < 0 SP L H H < 0, L > 0 H ≥ L SP L H H > 0, L < 0 H ≤ L SP Case 3 (Always ON) |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |