| Zakładka z wyszukiwarką danych komponentów |
|
AS3607 Arkusz danych(PDF) 59 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3607 Arkusz danych(HTML) 59 Page - ams AG |
|
59 / 71 page ![]() www.austriamicrosystems.com Revision 1.03 58 - 70 AS3606 AS3607 2v2 Data Sheet - R e g i s t e r D e f i n i t i o n Table 50. Third Interrupt Register Name Base Default IRQENRD_2 2-wire serial 00h Offset: 25h Third Interrupt Register Please be aware that writing to this register will enable/disable the corresponding interrupts, while reading gets the actual interrupt status and will clear the register at the same time. It is not possible to read back the interrupt enable/disable settings. This register is reset at a VDD27-POR or XRES input. Bit Bit Name Default Access Bit Description 7 CHG_TEMP_IRQ (status change) 0 W Battery over-temperature interrupt setting 0: disable 1: enable interrupt if CHG_TEMP status bit changes CHG_TEMP x R Battery over-temperature status reading 0: battery temperature below off-threshold 1: battery temperature was too high and the charger was turned off. The charger will be turned on again, when the temperature gets below the on- threshold 6 CHG_EOC_IRQ (status change) 0 W Charger end of charge interrupt setting. 0: disable 1: enable interrupt if CHG_EOC status bit changes CHG_EOC x R Charger end of charge status reading 0: battery charging in progress 1: charging is complete, charging current is below selected level of nominal current, charger was turned off. 5 CHG_NoBAT_IRQ (status change) 0 W Charger no battery interrupt setting 0: disable 1: enable interrupt if CHG_NoBat status bit changes CHG_NoBat x R Charger no battery status reading 0: battery connected 1: no battery detected at VBATSW pin 4 CHG_DET_IRQ (status change) 0 W Charger detect interrupt setting. 0: disable 1: enable interrupt if CHG_DET status bit changes CHG_DET x R Charger detect status reading 0:charger disconnected 1: charger connected 3- 0 n/a 2 ICURR_LV_IRQ (level) 0 W Current sink undervoltage interrupt setting. 0: disable 1: enable interrupt if the outputvoltage of one of the current sinks gets below the target regulation voltage x R Current sink undervoltage status reading 0: normal voltage on ICURR1 and ICURR2 1: voltage at ICURR1 or ICURR2 dropped below target voltage |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |