| Zakładka z wyszukiwarką danych komponentów |
|
CPCI350DC Arkusz danych(PDF) 2 Page - C&D Technologies |
|
|
|||||||||||||||||||||||||||||
CPCI350DC Arkusz danych(HTML) 2 Page - C&D Technologies |
|
2 / 4 page ![]() cPCI 350DC 9/2001 REV C Page 2 Remote Inhibit (INH#) Secondary referenced, active low, TTL compatible signal in- hibits all outputs upon activation. Power Fail Warning (FAL#) Secondary referenced, active low, TTL compatible signal in- dicates output failure. Enable (EN#) Short pin on connector will enable power supply output when the mating pin is grounded. Supply will not power up until this pin is engaged to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating con- nector. Temperature Warning (DEG#) Open collector indicates internal temperatures are approach- ing the thermal shutdown limit. Fault Indicator Red LED will be ON if output voltages are not within specifi- cation. Power Present LED Green LED will be ON when input voltage is present and above the minimum requirement. Cooling 400 lfm of airflow required to maintain full output power at 0- 50°C ambient. At 200 lfm, the output power is derated to 175W. Temperature 0-70°C operating range with full output power achievable over the range of 0-50°C. Between 50°C and 70°C, output power derates linearly from 350W to 175W. Storage temperature limits are –20 to +85°C. Altitude Operating: -200 to +10,000 feet with ambient temperature derating above 5,000 feet in accordance with the adiabatic lapse rate. INPUT CHARACTERISTICS PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Input Operating Voltage Vin 36 75 VDC Input Voltage With Stand 34 75 VDC Inrush Current 36VDC input 18 APK 72VDC input 36 APK Current Share Active current sharing is employed on outputs V1, V2, and V3. Accuracy exceeds 10% of maximum rated load. N max = 4. Output V4 to share within 40% of maximum rated load by means of droop response. Remote Sense Outputs V1, V2, and V3 capable of compensating up to 0.5VDC of line drop. Unit automatically reverts to local sens- ing in the event that the sense leads are opened for any reason. Unit is protected against reversed or shorted sense leads. Output Power 350W continuous maximum, with 400lfm airflow at a maxi- mum ambient of 50°C. Output power derates linearly to 175W at 70°C ambient or 200lfm of airflow at 50°C. Overload Protection Outputs are individually protected against overloads and in- definite short circuit with automatic recovery upon removal of the fault condition. Over Voltage Protection Output V1 OVP set at 6.0V ± 0.5VDC. Output V2 OVP set at 4.3V ± 0.5VDC. The power supply will shut down and latch off under an OVP fault condition. Restart of the unit is ac- complished by cycling of the input power. OverTemperature Protection Thermal switch shuts down the power supply in the event that critical temperatures are exceeded. Unit will automati- cally restart when acceptable temperatures are restored. Output Fault Isolation Output isolation diodes are present in all outputs to isolate faults within a failed power supply. |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |