| Zakładka z wyszukiwarką danych komponentów |
|
CPCI500DC Arkusz danych(PDF) 2 Page - C&D Technologies |
|
|
|||||||||||||||||||||||||||||
CPCI500DC Arkusz danych(HTML) 2 Page - C&D Technologies |
|
2 / 4 page ![]() 2 cPCI500-DC REV D 8/2002 Product: www.cdpowerelectronics.com Remote Inhibit (INH#) Secondary referenced, active low, TTL compatible signal inhibits all outputs upon activation. Power Fail Warning (FAL#) Open collector signal indicates output failure. Active low. Enable (EN#) Short pin on connector will enable power supply output when the mating pin is grounded. Supply will not power up until this pin is engaged to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector. Temperature Warning (DEG#) Open collector indicates internal temperatures are approaching the thermal shutdown limit. Active low. Fault Indicator LED A red LED will be ON if output voltages are not within specification. Power Present LED A green LED will be ON when input voltage is present and above the minimum requirement. Cooling 400lfm of airflow required to maintain full output power at 0- 50°C ambient. Additional data on operation below 400lfm is available in Application Note ACAN-01. Temperature Full output power achievable over the range of 0-50°C. Storage temperature limits are –20 to +85°C. Additional data on operation above 50°C is available in Application Note ACAN-01. Altitude Operating: -200 to +10,000 feet with ambient temperature derating above 5,000 feet in accordance with the adiabatic lapse rate. Inhibit Indicator LED (Yellow) A yellow LED will be ON when the outputs are inhibited. Transient Response For a step load change of 50%-100%-50%, the peak output excursion will not exceed 8% of nominal voltage, and will recover to within 1% of nominal voltage within 200 microseconds. Current Share Active current sharing is employed on Outputs V1, V2 and V3. Remote Sense Outputs V1, V2, and V3 are capable of compensating up to 0.3VDC of line drop. Unit automatically reverts to local sensing in the event that the sense leads are opened for any reason. Unit is protected against reversed or shorted sense leads. Output Power 500W continuous maximum, with 400lfm airflow at a maximum ambient of 50°C. Overload Protection Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition. Over Voltage Protection All outputs have over voltage protection at 125% typical (135% max.) of nominal. Over Temperature Protection Outputs are individually protected against over temperature. Outputs will automatically restore upon recovery to acceptable temperatures. Output Fault Isolation Output isolation diodes are present in all outputs to isolate faults within a failed power supply. IPMI Option An I 2 C board is available as a factory-installed option to provide an IPMI interface to the SM bus. Status functions include output voltage and current levels as well as the DEG warning. Output inhibit control can be toggled under software command. See Application Note ACAN-02 for satellite controller specification, ACAN-03 for firmware update procedure and ACAN-04 for test procedure. SPECIFICATIONS,ALLMODELS |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |