10 / 28 page ![]() Charging a lead acid battery AN3971 10/28 Doc ID 022119 Rev 2 3 Charging a lead acid battery A proper charging profile is important to guarantee a long battery lifetime. The following figure shows the correct voltage/current charging profile (for a single cell only): Figure 9. Typical SLA battery charging curve Some of the charging constraints are given below and must be applied to all types of lead acid batteries. 1. Starting from a battery discharge, the maximum current must be lower than a value of C/4 (where C is the maximum battery capacity in Ampere hour [Ah]) →I_batt_max = 0.25 * C 2. In any charging step, the voltage applied must not be greater than the gassing voltage →V_batt_max = 2.4 V per cell 3. During the recharge and up to 100% of the previous discharge capacity, the current should be controlled to maintain a voltage lower than the gassing voltage →to reduce charge time, this voltage can be just below the gassing voltage. |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|