Numer części LMS12
Szczegółowy opis  12-bit Cascadable Multiplier-Summer
PDF  9 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Producent  LODEV [LOGIC Devices Incorporated]
Strona internetowa  http://www.logicdevices.com
Logo LODEV - LOGIC Devices Incorporated

LMS12 Arkusz danych(HTML) 2 Page - LOGIC Devices Incorporated

  LMS12 Datasheet HTML 1Page - LOGIC Devices Incorporated LMS12 Datasheet HTML 2Page - LOGIC Devices Incorporated LMS12 Datasheet HTML 3Page - LOGIC Devices Incorporated LMS12 Datasheet HTML 4Page - LOGIC Devices Incorporated LMS12 Datasheet HTML 5Page - LOGIC Devices Incorporated LMS12 Datasheet HTML 6Page - LOGIC Devices Incorporated LMS12 Datasheet HTML 7Page - LOGIC Devices Incorporated LMS12 Datasheet HTML 8Page - LOGIC Devices Incorporated LMS12 Datasheet HTML 9Page - LOGIC Devices Incorporated  
Zoom Inzoom in Zoom Outzoom out
 2 / 9 page
background image
DEVICES INCORPORATED
LMS12
12-bit Cascadable Multiplier-Summer
Multiplier-Summers
08/16/2000–LDS.S12-J
2
FIGURE 1.
FLOW DIAGRAM FOR 5-TAP FIR FILTER
A3
h3
A4
h4
Z–1
A2
h2
A1
h1
h0
y(n)
x(n)
y(n)
h0
h1
h2
h3
h4
x(n)
Z–1
Z–1
Z–1
Z–1
Z–1
Z–1
Z–1
Z–1
A0
APPLICATIONS
The LMS12 is designed specifically for
high-speed FIR filtering applications
requiring a throughput rate of one
output sample per clock period. By
cascading LMS12 units, the transpose
form of the FIR transfer function is
implemented directly, with each of the
LMS12 units supplying one of the
filter weights, and the cascaded
summers accumulating the results.
The signal flow graph for a 5-tap FIR
filter and the equivalent implementa-
tion using LMS12’s is shown in
Figure 1.
The operation of the 5-tap FIR filter
implementation of Figure 1 is depicted
in Table 1. The filter weights h4 - h0
are assumed to be latched in the B
input registers of the LMS12 units.
The x(n) data is applied in parallel to
the A input registers of all devices.
For descriptive purposes in the table,
the A register contents and sum
output data of each device is labelled
according to the index of the weight
applied by that device; i.e., S0 is
produced by the rightmost device,
which has h0 as its filter weight and
A0 as its input register contents. Each
column represents one clock cycle,
with the data passing a particular
point in the system illustrated across
each row.



Html Pages

1 2 3 4 5 6 7 8 9


Arkusz danych Pobierz

Go To PDF Page


Link URL



Czy Alldatasheet okazała się pomocna?  [ DONATE ] 

O Alldatasheet   |   Reklama   |   Kontakt   |   Polityka prywatności   |   Link do karty katalogowej    |   Linki   |   Lista producentów
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com