| Zakładka z wyszukiwarką danych komponentów |
|
RFSA3714 Arkusz danych(PDF) 13 Page - RF Micro Devices |
|
|
|||||||||||||||||||||||||||||
RFSA3714 Arkusz danych(HTML) 13 Page - RF Micro Devices |
|
13 / 20 page ![]() RF Micro Devices Inc. 7628 Thorndike Road, Greensboro, NC 27409-9421 DS141203 For sales or technical support, contact RFMD at +1.336.678.5570 or customerservice@rfmd.com. The information in this publication is believed to be accurate. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents or other rights of third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change component circuitry, recommended application circuitry and specifications at any time without prior notice. 13 of 20 RFSA3714 Evaluation Board Jumper Programming Jumpers Connector Signal Position U1 Connection Comment S1 P3 Logic Voltage 0 VDD (From P6) 1 VIO (From P5) S2 PBar/S 0 GND Parallel Mode 1 U1_VDD Serial Mode S6 P4 LE OPEN LE All Other Modes INSTALLED LE (From P5 Pin 3) Serial Mode Using P5 Note: Default jumper settings are BOLD. Evaluation Board Programming Using USB Interface Serial Mode All programming jumpers on the evaluation board are set to the default values indicated in the table. Refer to the Control Bit Generator (CBG) Software Reference Manual for detailed instructions on how to setup the software for use. Apply the supply voltag e to P6. Select ‘RFSA3714’ from the RFMD parts list of the CBG user interface. Set the attenuation value using the CBG user interface. The attenuator is set to the desired state and measurement can be taken. Latched Parallel Mode Evaluation board programming jumper S2 is set to ‘0’. All other programming jumpers are not required and can be set to any position. Refer to the Control Bit Generator Software Reference Manual for detailed instructions on how to set up the software for use. Apply the supp ly voltage to P6. Select ‘RFSA3714-P’ from the RFMD part list of the CBG user interface. Set the attenuation value using the CBG user interface. The attenuator is set to the desired state and measurements can be taken. Evaluation Board Programming Using External Bus Serial Mode The configuration allows the user to control the attenuator through the P5 connector using an external harness. Remove the USB interface board if it is currently installed on the evaluation board. Connect a user-supplied harness to the P5 connector. Note that the top row of P5 contains the serial bus signals and the bottom row is ground. Programming jumper S1 is set to ‘0’ and S2 is set to ‘1’. Jumper S6 is installed and allows the LE signal to be routed from the P5 connector to the attenuator. Apply the supply voltage P6. Send the appropriate signals onto the serial bus lines in accordance with the Serial Mode Timing Diagram. The attenuator is set to the desired state and measurements can be taken. |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |