9 / 17 page ![]() 1.0 Functional Description (Continued) 1.4 TEMPERATURE DATA FORMAT Temperature data can be read from the Temperature and Set Point registers; and written to the Set Point registers. Tem- perature data can be read at any time, although reading faster than the conversion time of the LM77 will prevent data from being updated. Temperature data is represented by a 10-bit, two’s complement word with an LSB (Least Signifi- cant Bit) equal to 0.5˚C: Temperature Digital Output Binary Hex +130˚C 01 0000 0100 104h +125˚C 00 1111 1010 0FAh +25˚C 00 0011 0010 032h +0.5˚C 00 0000 0001 001h 0˚C 00 0000 0000 000h −0.5˚C 11 1111 1111 3FFh −25˚C 11 1100 1110 3CEh −55˚C 11 1001 0010 392h 1.5 SHUTDOWN MODE Shutdown mode is enabled by setting the shutdown bit in the Configuration register via the Serial Bus. Shutdown mode reduces power supply current to 5 µA typical. T_CRIT_A is reset if previously set. Since conversions are stoped during shutdown, T_CRIT_A and INT will not be operational. The Serial Bus interface remains active. Activity on the clock and data lines of the Serial Bus may slightly increase shutdown mode quiescent current. Registers can be read from and written to in shutdown mode. The LM77 takes miliseconds to respond to the shutdown command. 1.6 INT AND T_CRIT_A OUTPUT The INT and T_CRIT_A outputs are open-drain outputs and do not have internal pull-ups. A ″high″ level will not be observed on these pins until pull-up current is provided from some external source, typically a pull-up resistor. Choice of resistor value depends on many system factors but, in gen- eral, the pull-up resistor should be as large as possible. This will minimize any errors due to internal heating of the LM77. The maximum resistance of the pull up, based on LM77 specification for High Level Output Current, to provide a 2 volt high level, is 30K ohms. 1.7 FAULT QUEUE A fault queue of up to 4 faults is provided to prevent false tripping when the LM77 is used in noisy environments. The 4 faults must occur consecutively to set flags as well as INT and T_CRIT_A outputs. The fault queue is enabled by set- ting bit 4 of the Configuration Register high (see Section 1.11). DS100136-6 Note: Event Interrupt mode is drawn as if the user is reading the part. If the user doesn’t read, the outputs would go low and stay that way until the LM77 is read. FIGURE 3. Temperature Response Diagram www.national.com 9 |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |