| Zakładka z wyszukiwarką danych komponentów |
|
LM8300 Arkusz danych(PDF) 13 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LM8300 Arkusz danych(HTML) 13 Page - National Semiconductor (TI) |
|
13 / 20 page ![]() 6.0 Power Save Mode (Low Power Stand-by) The power consumption of the controller can be minimized by enabling the low power stand by mode. The power save mode can be controlled internally by sending a command of $A2 to the controller, externally by pulling the SHUTDOWN pin low, or by issuing a driver shutdown command of $A8. The self power down mode is enabled/disabled by sending a command of $A2 to the controller. When enabled, the con- troller automatically goes into low power stand by if no more touch activity is detected or if there is no UART communica- tion. The controller automatically comes out of low power stand by mode when a touch is detected on the touch panel or if an incoming communication on the UART is detected. In the low power stand by mode, all activity is disabled, includ- ing the oscillator. Also, the LED pin is driven high. To wake up the controller on the UART, the wake up command byte must be sent, followed by a minimum time delay of 1ms for the LM8500 and 3ms for the LM8300/8400 before sending any command byte. The delay time is needed to allow the oscillator to restart and stabilize. Table 3 shows the average startup time for a given operating frequency. The SHUTDOWN pin will shut down the controller when pulled low. When the SHUTDOWN pin is pulled low, the controller will continue to be in the low power stand by mode until the pin is pulled high or released. While the SHUT- DOWN pin is pulled low, all activities are stopped and any touch or communication will be ignored. Immediately follow- ing the SHUTDOWN pin being released or pulled high, the controller clears the UART transmit and receive buffers and resumes normal operation. The controller can be put in the low power stand by mode by sending a $A8 command to it. Upon receiving this command, the controller goes into low power stand by mode. If the self power down mode is enabled and the controller is put into low power stand by mode, the controller will wake up if the wake up command ($A7) is received or if a touch is detected on the touch panel. If the self power down mode is disabled and the controller is put into low power stand by mode, the controller can only be woken up if it receives the wakeup command. After the controller wakes up, the UART transmit and receive buffers are cleared and resume normal opera- tion. TABLE 3. Startup Times CKI Frequency Startup Time 10 MHz 1–10 ms 3.33 MHz 3–10 ms 7.0 Averaging Algorithm To achieve better accuracy and noise filtering, each X, Y, and Z coordinate is oversampled by specific amount. The pos- sible oversampling settings are 1, 2, 4, 8, 16, and 32. The factory setting is 8. The greater the oversampling, the greater the accuracy, but the lower the CPPS. Samples per coordinate vs. CPPS for LM8300/8400 Samples per coordinate Coordinate pairs per second (CPPS) 1 250 2 220 4 190 8 150 16 100 32 65 Samples per coordinate vs. CPPS for LM8500 Samples per coordinate Coordinate pairs per second (CPPS) 1 500 2 430 4 360 8 270 16 190 32 110 7.1 Delta Algorithm The delta filter is used to remove large variations in sampled values due to noise and glitches. The delta filter tries to predict where the next coordinate could be. This is done by taking the two previous coordinates and subtracting one from the other, producing a delta value. This delta value is then added or subtracted to the last coordinate. The result- ing value is the predicted coordinate. If the new sampled coordinate is close to this predicted value, then the new value is accepted as valid and is passed to the focus algo- rithm, provided the focus algorithm is enabled. If the new sampled coordinate is not close to the predicted coordinate, then the value is discarded and is stored to be used in the following delta calculations. The number by which the new sampled coordinate can differ from the predicted coordinate is controlled by setting the Set Max Delta value. The Set Max Delta value can be from a value of 0-63. The factory default is 8. 7.2 Focus Algorithm The focus algorithm removes some inaccuracy and noise that could cause the coordinate to differ only by a couple of pixels. The focus algorithm is used to eliminate the "jittering" effect of the pointer when the pointer is stationary. The focus algorithm compares the value of the previous stored value to the value passed from the delta algorithm and determines if the difference is greater than or equal to the Set Focus Value. If the difference is greater or equal to the value in Set Focus Value then the new coordinate is sent out through the UART and stored as the previous value. If the difference is less than the Set Focus Value then the value is discarded and the stored valued is set through the UART. The amount of difference between the new coordinate and the old coordinate is set in the Set Focus Value. This value can be from 0-63 with a value of 0 disabling the focus algorithm. The factory default is 4. www.national.com 13 |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |