| Zakładka z wyszukiwarką danych komponentów |
|
ATS625LSG Arkusz danych(PDF) 4 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
ATS625LSG Arkusz danych(HTML) 4 Page - Allegro MicroSystems |
|
4 / 21 page ![]() True Zero-Speed Low-Jitter High Accuracy Gear Tooth Sensor ATS625LSG 4 Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com OPERATING CHARACTERISTICS with 60+2 reference target Operational Air Gap AG Measured from sensor branded face to target tooth 0.5 – 2.5 mm Relative Timing Accuracy, Sequen- tial Mechanical Rising Edges ERRRR Relative to measurement taken at AG = 1.5 mm – – ±0.4 deg. Relative Timing Accuracy, Sequen- tial Mechanical Falling Edges ERRFF Relative to measurement taken at AG = 1.5 mm – – ±0.4 deg. Relative Timing Accuracy, Signa- ture Mechanical Rising Edge4 ERRSIGR Relative to measurement taken at AG = 1.5 mm – – ±0.4 deg. Relative Timing Accuracy, Signa- ture Mechanical Falling Edge5 ERRSIGF Relative to measurement taken at AG = 1.5 mm – – ±1.5 deg. Relative Repeatability, Sequential Rising and Falling Edges6 TθE 360° Repeatability, 1000 edges; peak-peak sinusoidal signal with BPEAK ≥ BIN(min) and 6° period – – 0.08 deg. Operating Signal7 BIN AG(min) < AG < AG(max) 60 – – G 1 Test condition is ICC(max) + 3 mA. 2 Upper limit is ICC(max) + 3 mA. 3 Power-on speed ≤ 200 rpm. Refer to the Sensor Description section for information on start-up behavior. 4 Detection accuracy of the update algorithm for the first rising mechanical edge following a signature region can be adversely affected by the magnetic bias of the signature region. Please consult with Allegro field applications engineering for aid with assessment of specific target geometries. 5 Detection accuracy of the update algorithm for the falling edge of the signature region is highly dependent upon specific target geometry. Please consult with Allegro field applications engineering for aid with assessment of specific target geometries. 6 The repeatability specification is based on statistical evaluation of a sample population. 7 Peak-to-peak magnetic flux strength required at Hall elements for complying with operational characteristics. Operating Characteristics, continued Valid at TA = –40°C to 150°C, TJ ≤TJ(max), over full range of AG, unless otherwise noted; typical operating parameters: VCC = 12 V and TA = 25°C Characteristic Symbol Test Conditions Min. Typ. Max. Units |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |