Back Button D4SL-N2FDG Datasheet HTML 9Page - Omron Electronics LLC D4SL-N2FDG Datasheet HTML 10Page - Omron Electronics LLC D4SL-N2FDG Datasheet HTML 11Page - Omron Electronics LLC D4SL-N2FDG Datasheet HTML 12Page - Omron Electronics LLC D4SL-N2FDG Datasheet HTML 13Page - Omron Electronics LLC D4SL-N2FDG Datasheet HTML 14Page - Omron Electronics LLC D4SL-N2FDG Datasheet HTML 15Page - Omron Electronics LLC D4SL-N2FDG Datasheet HTML 16Page - Omron Electronics LLC D4SL-N2FDG Datasheet HTML 17Page - Omron Electronics LLC Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 27 page
background image
D4SL-N / D4SL-NSK10-LK
@
13
Contact Form
Indicates conditions where the Key is inserted and the lock is applied.
Model
Contact
(door open/
closed detection
and lock monitor)
Contact Form
Operating pattern
Remarks
Lock
monitor
Door open/
closed
detection
D4SL-N
@A@@-@
1NC/1NO+
1NC/1NO
Only NC contact 11-12 has a
certified direct opening
mechanism.
The terminals 42-11, 34-33, and
64-63 can be used as unlike
poles.
D4SL-N
@B@@-@
1NC/1NO+2NC
Only NC contact 11-12 has a
certified direct opening
mechanism.
The terminals 42-11, 34-33, and
62-61 can be used as unlike
poles.
D4SL-N
@C@@-@
2NC+1NC/1NO
Only NC contact 11-12 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-11, 32-31, and
64-63 can be used as unlike
poles.
D4SL-N
@D@@-@
2NC+2NC
Only NC contact 11-12 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-11, 32-31, and
62-61 can be used as unlike
poles.
D4SL-N
@S@@-@
1NC/1NO+
1NC/1NO
Only NC contact 21-22 has a
certified direct opening
mechanism.
The terminals 42-41, 22-21, 34-
33, and 64-63 can be used as
unlike poles.
D4SL-N
@T@@-@
1NC/1NO+2NC
Only NC contact 21-22 has a
certified direct opening
mechanism.
The terminals 42-41, 22-21, 34-
33, and 62-61 can be used as
unlike poles.
D4SL-N
@U@@-@
2NC+1NC/1NO
Only NC contact 21-22 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-41, 22-21, 32-
31, and 64-63 can be used as
unlike poles.
D4SL-N
@V@@-@
2NC+2NC
Only NC contact 21-22 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-41, 22-21, 32-
31, and 62-61 can be used as
unlike poles.
42
64
63
41
12
Door open/closed
detection
Lock monitor
11
34
33
2
8
1
5
7
6
On
Stroke
42-11
34-33
64-63
Operation Key Insertion
completion position
Extraction
completion position
Lock position
42
62
61
41
12
11
34
33
Door open/closed
detection
Lock monitor
2
8
1
5
7
6
On
Stroke
42-11
34-33
62-61
Operation Key Insertion
completion position
Extraction
completion position
Lock position
42
64
63
41
12
11
32
31
Door open/closed
detection
Lock monitor
2
8
1
5
7
6
On
Stroke
42-11
32-31
64-63
Operation Key Insertion
completion position
Extraction
completion position
Lock position
42
62
61
41
12
11
31
32
Door open/closed
detection
Lock monitor
2
8
1
5
7
6
On
Stroke
42-11
32-31
62-61
Operation Key Insertion
completion position
Extraction
completion position
Lock position
42
64
63
41
34
33
21
22
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7
6
On
Stroke
42-41
22-21
34-33
64-63
Operation Key Insertion
completion position
Extraction
completion position
Lock position
42
62
61
41
34
33
21
22
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7
6
On
Stroke
42-41
22-21
34-33
62-61
Operation Key Insertion
completion position
Extraction
completion position
Lock position
42
64
63
41
32
31
21
22
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7
6
On
Stroke
42-41
22-21
32-31
64-63
Operation Key Insertion
completion position
Extraction
completion position
Lock position
42
62
61
41
32
31
21
22
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7
6
On
Stroke
42-41
22-21
32-31
62-61
Operation Key Insertion
completion position
Extraction
completion position
Lock position



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27


Arkusz danych Pobierz

Go To PDF Page


Link URL



Czy Alldatasheet okazała się pomocna?  [ DONATE ] 

O Alldatasheet   |   Reklama   |   Kontakt   |   Polityka prywatności   |   Link do karty katalogowej    |   Linki   |   Lista producentów
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com