| Zakładka z wyszukiwarką danych komponentów |
|
ADE7762 Arkusz danych(PDF) 22 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7762 Arkusz danych(HTML) 22 Page - Analog Devices |
|
22 / 28 page ![]() ADE7762 Preliminary Technical Data Rev. PrB | Page 22 of 28 POWER MEASUREMENT CONSIDERATIONS Calculating and displaying power information always have some associated ripple that depends on the integration period used in the MCU to determine average power as well as the load. For example, at light loads, the output frequency can be 10 Hz. With an integra- tion period of two seconds, only about 20 pulses are counted. The possibility of missing one pulse always exists since the ADE7762 output frequency is running asynchronously to the MCU timer. This would result in a 1-in-20 or 5% error in the power measure- ment. To remedy this, an appropriate integration time should be considered to achieve the desired accuracy. MODE SELECTION OF THE SUM OF THE THREE ACTIVE ENERGIES The ADE7762 can be configured to execute the arithmetic sum of the three active energies, Wh = WhΦA + WhΦB + WhΦC, or the sum of the absolute value of these energies, Wh = |WhΦA| + |WhΦB| + |WhΦC|. The selection between the two modes can be made by setting the ABS pin. Logic high and logic low applied on the ABS pin correspond to the arithmetic sum and the sum of absolute values, respectively. When the sum of the absolute values is selected, the active energy from each phase is always counted positive in the total active energy. It is particularly useful in 3-phase 4-wire instillation where the sign of the active power should always be the same. If the meter is misconnected to the power lines, that is, CT connected in the wrong direction then the total active energy recorded without this solution can be reduced by two- thirds. The sum of the absolute values assures that the active energy recorded represents the actual active energy delivered. In this mode, the reverse power pin still detects when negative power is present on any of the three phase inputs, but energy continues to accumulate regardless of the sign. |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |