| Zakładka z wyszukiwarką danych komponentów |
|
WM8591GEDS/V Arkusz danych(PDF) 35 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM8591GEDS/V Arkusz danych(HTML) 35 Page - Wolfson Microelectronics plc |
|
35 / 51 page ![]() Production Data WM8591 w PD Rev 4.0 December 2005 35 ATTACK AND DECAY TIMES The limiter and ALC have different attack and decay times which determine their operation. However, the attack and decay times are defined slightly differently for the limiter and for the ALC. DCY and ATK control the decay and attack times, respectively. Decay time (Gain Ramp-Up). When in ALC mode, this is defined as the time that it takes for the PGA gain to ramp up across 90% of its range (e.g. from –21dB up to +20 dB). When in limiter mode, it is defined as the time it takes for the gain to ramp up by 6dB. The decay time can be programmed in power-of-two (2 n) steps. For the ALC this gives times from 33.6ms, 67.2ms, 134.4ms etc. to 34.41s. For the limiter this gives times from 1.2ms, 2.4ms etc., up to 1.2288s. Attack time (Gain Ramp-Down) When in ALC mode, this is defined as the time that it takes for the PGA gain to ramp down across 90% of its range (e.g. from +20dB down to -21dB gain). When in limiter mode, it is defined as the time it takes for the gain to ramp down by 6dB. The attack time can be programmed in power-of-two (2 n) steps, from 8.4ms, 16.8ms, 33.6ms etc. to 8.6s for the ALC and from 250us, 500us, etc. up to 256ms. The time it takes for the recording level to return to its target value or static gain value therefore depends on both the attack/decay time and on the gain adjustment required. If the gain adjustment is small, it will be shorter than the attack/decay time. REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION LC Attack (Gain Ramp-down) Time 3:0 ATK[3:0] 0010 ALC mode 0000: 8.4ms 0001: 16.8ms 0010: 33.6ms… (time doubles with every step) 1010 or higher: 8.6s Limiter Mode 0000: 250us 0001: 500us… 0010: 1ms (time doubles with every step) 1010 or higher: 256ms LC Decay (Gain Ramp-up) Time R18 (12h) 0010010 ALC Control 3 7:4 DCY [3:0] 1001 ALC mode 0000: 33.5ms 0001: 67.2ms 0010: 134.4ms ….(time doubles for every step) 1001: 17.15s 1010 or higher: 34.3s Limiter mode 0000: 1.2ms 0001: 2.4ms 0010: 4.8ms ….(time doubles for every step) 1001: 614.4ms 1010 or higher: 1.2288s ZERO CROSS The PGA has a zero cross detector to prevent gain changes introducing noise to the signal. In ALC mode the register bit ALCZC allows this to be turned off if desired. REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION R17 (11h) 0010001 ALC Control 2 7 ALCZC 1 (enabled) PGA Zero Cross Enable: 0 : disabled 1: enabled |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |