Back Button E5CN-R2TU Datasheet HTML 11Page - Omron Electronics LLC E5CN-R2TU Datasheet HTML 12Page - Omron Electronics LLC E5CN-R2TU Datasheet HTML 13Page - Omron Electronics LLC E5CN-R2TU Datasheet HTML 14Page - Omron Electronics LLC E5CN-R2TU Datasheet HTML 15Page - Omron Electronics LLC E5CN-R2TU Datasheet HTML 16Page - Omron Electronics LLC E5CN-R2TU Datasheet HTML 17Page - Omron Electronics LLC E5CN-R2TU Datasheet HTML 18Page - Omron Electronics LLC E5CN-R2TU Datasheet HTML 19Page - Omron Electronics LLC Next Button
Zoom Inzoom in Zoom Outzoom out
 15 / 24 page
background image
Digital Temperature Controllers
E5CN/E5CN-U
15
Operation
■ Outline of Operation Procedures
The following diagram illustrates the entire setting level. A password is required to enter the advance function setting level and the calibration level.
Some parameters may not be displayed depending on the protection settings and operation conditions.
The control operation will stop when switching from operation level to initial setting level.
]
Note: 1. Operation level entered for software reset.
2. You cannot move to other levels by operating the keys on the front panel from the calibration level. You must turn OFF the power supply.
3. You can move only to the operation level by operating the keys on the front panel from the manual control level.
4. The time taken to move to the protect level can be adjusted by changing the “Move to protect level time” setting.
Input password.
Input password.
Set value 1201
Control in progress
Control stopped
Operation Level
Not displayed for some models
Level change
Initial Setting Level
Communications
Setting Level
Adjustment Level
Protect Level
Power ON
Press the
Level Key
less than 1 s.
Manual
Control Level
Press the Level
Key for at least 1 s.
Starting in manual mode
Starting in automatic mode
Manual
Mode
Press the Level
Key for at least 1 s.
Press the
Level + Mode
Keys.
for at least 1 s
Calibration Level
Press the
Level + Mode Keys;
display will flash.
Advanced Function
Setting Level
(See
note 1.)
(See
note 2.)
(See
note 3.)
a-m
C
25
100
C
25
100
C
Set value
−169
Press the Level Key
for at least 3 s while
a-m is displayed.
Press the Level Key
for at least 1 s;
display will flash.
Press the
Level Key for
at least 1 s.
Press the Level Key
for at least 1 s;
display will flash.
Press the Level Key for
at least 3 s.
Control stops .
Press the Level +
Mode Keys for at least
3 s. (See note 4.)
Press the Level Key
for less than 1 s.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24


Arkusz danych Pobierz

Go To PDF Page


Link URL



Czy Alldatasheet okazała się pomocna?  [ DONATE ] 

O Alldatasheet   |   Reklama   |   Kontakt   |   Polityka prywatności   |   Link do karty katalogowej    |   Linki   |   Lista producentów
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com