| Zakładka z wyszukiwarką danych komponentów |
|
E5CN-R2TU Arkusz danych(PDF) 17 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CN-R2TU Arkusz danych(HTML) 17 Page - Omron Electronics LLC |
|
17 / 24 page ![]() Digital Temperature Controllers E5CN/E5CN-U 17 Initial Setting Level Advanced Function Setting Level in-l 0 dp 0 in-t 5 in-h 100 d-u c sl-h 1300 C sl-l -200 C cntl onof s-hc stnd st on ptrn off cp 20 c-cp 20 oreV or-r alt1 2 alt2 2 alt3 2 tr-t off tr-h 100.0 tr-l 0.0 o1-t 4-20 amoV 0 Input type Scaling upper limit Scaling lower limit Decimal point Temperature unit SP upper limit SP lower limit PID ON/OFF Standard or heating/ cooling ST Program pattern Control period (heating) Control period (cooling) Direct/reverse operation Alarm 1 type Alarm 2 type Alarm 3 type Transfer output type Transfer output upper limit Transfer output lower limit Linear current output init off eV-m 1 eV-1 none eV-2 stop mspu off spru m rest a al1n n-o alh1 0.2 C al2n n-o alh2 0.2 C al3n n-o alh3 0.2 C hbu on hbl off hbh 0.1 st-b 15.0 C alfa 0.65 inf 0.0 pVad off o-dp off ret off a1lt off a2lt off a3lt off prlt 3 sero off cjc on rlrV off colr red pV-b 5.0 C a1on 0 a2on 0 a3on 0 a1of 0 a2of 0 a3of 0 istp ins1 mVse off amad off rt off hsu on hsl off hsh 0.1 lba 0 lbal 8.0 C lbab 3.0 C out1 o out2 none alm1 alm1 alm2 alm2 csel on t-u m alsp sp-m cmoV 0 Parameter initialization Number of multi-SP uses Event input assignment 1 Event input assignment 2 Multi-SP uses SP ramp time unit Alarm 1 open in alarm Alarm 1 hysteresis Alarm 2 open in alarm Alarm 2 hysteresis Alarm 3 open in alarm Alarm 3 hysteresis Heater burnout detection Heater burnout latch ST stable range α Input digital filter Additional PV display MV display Automatic return of display mode Alarm 1 latch Alarm 2 latch Alarm 3 latch Move to protect level time Input error output Cold junction compensating method MB command logic switching PV display color PV stable range Alarm 1 ON delay Alarm 2 ON delay Alarm 3 ON delay Alarm 1 OFF delay Alarm 2 OFF delay Alarm 3 OFF delay Input shift type Additional MV for stop/error RT SSR failure detection SSR failure latch SSR failure hysteresis LBA detection time LBA detection threshold LBA detection width Control output 1 assignment Control output 2 assignment Alarm output 1 assignment Alarm output 2 assignment Display text switch Soak time unit Alarm SP selection Move to calibration level Press the Level Key less than 1 s. Move by setting password ( −169). Press the Level Key for at least 1 s. Two SPs: 1 Four SPs: 2 For input type of analog Limit the set point. Set the pulse output cycle. Linear output Linear output °C, °F a For input type of temperature For input type of temperature, standard, or PID When assigning PID or control output to pulse output Displayed when initial setting/ communications protection is set to 0 Move to advanced function setting level Heater burnout hysteresis Standby sequence reset method Auto/manual switching function addition a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |