| Zakładka z wyszukiwarką danych komponentów |
|
LT7184SRVPBF Arkusz danych(PDF) 45 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LT7184SRVPBF Arkusz danych(HTML) 45 Page - Analog Devices |
|
45 / 52 page ![]() Data Sheet LT7184S analog.com Rev. 0 45 of 52 COMMAND CODE DESCRIPTION TYPE PAGED FORMAT UNITS NVM DEFAULT VOUT_MODE 0x20 Output voltage format and exponent. R Byte N Register 0x60 VOUT_COMMAND 0x21 Nominal output voltage set point. R/W Word Y IEEE or UL16 V Y 0.5V (0x3800) VOUT_MAX 0x24 The upper limit on the commanded output voltage. R/W Word Y IEEE or UL16 V Y 0.537V (0X384c) VOUT_MARGIN_HIGH 0X25 Margin high output voltage set point. R/W Word Y IEEE or UL16 V Y 0.525V (0X3833) VOUT_MARGIN_LOW 0X26 Margin low output voltage set point. R/W Word Y IEEE or UL16 V Y 0.475V (0X379A) VOUT_TRANSITION_RATE 0x27 Rate the output voltage changes when VOUT is commanded to a new value. R/W Word Y IEEE or L11 V/ms Y 0.25V/ms (0x3400) FREQUENCY_SWITCH 0x33 Switching frequency of the regulator. R/W Word N IEEE or L11 kHz Y 1000.0 (0x63D0) VIN_ON 0x35 Input voltage at which the unit should start power conversion. R/W Word Y IEEE or L11 V Y Ch0:1.5V (0x3E00) Ch1:1.4V (0x3D9A) VIN_OFF 0x36 Input voltage at which the unit should stop power conversion. R/W Word y IEEE or L11 V Y Ch0:1.45V (0x3DCD) Ch1:1.35V (0x3D66) VOUT_OV_FAULT_LIMIT 0x40 Output overvoltage fault limit. R/W Word Y IEEE or L11 V Y 0.55V (0x3866) VOUT_OV_FAULT_RESPONSE 0x41 Action to be taken by the device when an output overvoltage fault is detected. R/W Byte Y Register Y 0xB8 VOUT_OV_WARN_LIMIT 0x42 Output overvoltage warning limit. R/W Word Y IEEE or L11 V Y 0.537V (0x384C) VOUT_UV_WARN_LIMIT 0x43 Output undervoltage warning limit. R/W Word Y IEEE or L11 V Y 0.467V (0x3779) VOUT_UV_FAULT_LIMIT 0x44 Output undervoltage fault limit R/W Word Y IEEE or L11 V Y 0.465V (0x3771) VOUT_UV_FAULT_RESPONSE 0x45 Action to be taken by the device when an output undervoltage fault is detected. R/W Byte Y Register Y 0x00 IOUT_OC_FAULT_RESPONSE 0x47 Action to be taken by the device when an output over the current fault is detected. R/W Byte Y Register Y 0x00 IOUT_OC_WARN_LIMIT 0x4A Output overcurrent warning limit. R/W Word Y IEEE or L11 A Y 11.0A (0x4980) |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |