46 / 52 page ![]() Data Sheet LT7184S analog.com Rev. 0 46 of 52 COMMAND CODE DESCRIPTION TYPE PAGED FORMAT UNITS NVM DEFAULT OT_FAULT_LIMIT 0x4F Internal overtemperature fault limit. R/W Word N IEEE or L11 C Y 160.0C (0x5900) OT_FAULT_RESPONSE 0x50 Action to be taken by the device when an internal overtemperature fault is detected. R/W Byte N Register Y 0xC0 OT_WARN_LIMIT 0x51 Internal overtemperature warning limit. R/W Word N IEEE or L11 C Y 140.0C (0x5860) VIN_OV_FAULT_RESPONSE 0x56 Action to be taken by the device when an input overvoltage fault is detected. R/W Byte Y Register Y 0xB8 VIN_UV_WARN_LIMIT 0x58 Input supply undervoltage warning limit. R/W Word Y IEEE or L11 V Y -1.0V (0xBC00) IIN_OC_WARN_LIMIT 0x5D Input supply overcurrent warning limit. R/W Word Y IEEE or L11 A Y 9.0A (0x4880) TON_DELAY 0x60 Time from RUNN and/or Operation command till an output rail turns on. R/W Word Y IEEE or L11 ms Y 0.0ms (0x0000) TON_RISE 0x61 Time from when the output starts to rise until the output voltage set point reaches the VOUT commanded value. R/W Word Y IEEE or L11 ms Y 1.0ms (0x3C00) TON_MAX_FAULT_LIMIT 0x62 Maximum time from the start of TON_RISE for VOUT to cross the VOUT_UV_FAULT_LIMIT. R/W Word Y IEEE or L11 ms Y 5.0ms (0x4500) TON_MAX_FAULT_RESPONSE 0x63 Action to be taken by the device when a TON_MAX_FAULT event is detected. R/W Byte Y Register Y 0x00 TOFF_DELAY 0x64 Time from RUNN and/or Operation command to the start of the TOFF_FALL ramp. R/W Word Y IEEE or L11 ms Y 0.0ms (0x0000) TOFF_FALL 0x65 Time from when the output starts to fall until the output reaches zero volts. R/W Word Y IEEE or L11 ms Y 2.0ms (0x4000) TOFF_MAX_WARN_LIMIT 0x66 Maximum allowed time after TOFF_FALL is completed for the output voltage to fall below the MFR_DISCHARGE _THRESHOLD. R/W Word Y IEEE or L11 ms Y 0.0ms (0x0000) STATUS_BYTE 0x78 One-byte summary of the unit's fault condition. R/W Byte Y Register STATUS_WORD 0x79 Two-byte summary of the unit's fault condition. R/W Word Y Register |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |