19 / 35 page ![]() 19 System pro M compact ® Supplementary devices Technical Data Signal contact/auxiliary switch S2C-S/H6R and auxiliary switch S2C – H6R according to EN 62019 rated current I th: 10 A min. rated voltage U Bmin: 24 V ~, 24 V ... min. rated operational current: 5 VA short-circuit withstand capacity: 230 V~ 1000 A with S 201 K 4 insulation coordination: according to DIN VDE 0110 Parts 1 and 2 – overvoltage category: III – surge voltage: 4 kV (1.2/50 µs) – pollution degree: 2 connection cross section: 0.75 ... 2.5 mm2 (up to 2 x 1.5 mm2) tightening torque: 1.2 Nm max. contact stability in vibration test according to DIN IEC 68-2-6-: 5 g, 20 sweep cycles 5 ... 150 ... 5 Hz at 24 VAC/DC, 5 mA automatic reclosing < 10 ms mech. service life: 10 000 operations The minimum rated operational current value applies in the case of operation and environmental conditions according to EN 60 204-1/1998 and EN 60 439-1/2000 if installed indoors and in clean ambient air: 24 VAC/DC, 5 mA (AC-12, DC-12) 1.2 Auxiliary switch type S2C-H6R Description The simple auxiliary switch without test functionality is appropriate for applications where it is only necessary to indicate the contact position of the circuit-breaker. Up to three S2C-H6R can be butt-mounted, including combinations with the signal contact/auxiliary switch SC2-S/H6R. Installation and technical data the same as for signal contact/auxiliary switch SC2-S/H6R, see preceding page and above. Installation and technical data the same as for signal contact/auxiliary switch SC2-S/H6R, see preceding page and above. 2. Shunt trip S2C-A Description For distance tripping of the MCB. The shunt release has a relay coil with an integrated contact which disconnects the coil and the coil voltage if the MCB trips, this prevents the flow of current in the case of sustained coil voltage. Technical data type: S2C - A1 S2C - A2 service voltage: 12 ... 60 V 110 ... 415 VAC and 110 ... 250 VDC AC 14 DC 12 DC 13 U e 400 V 230 V I e 1 A 2 A U e 220 V 110 V I e 1 A 1.5 A U e 60 V 24 V U e 1.5 A 4 A STOTZ-Shunt trip with automatic disconnecting within 10 milliseconds UB = Un + 10 – 30 % UB IBmax UB IBmax S2C-A1 12 VDC 2.2 A S2C-A2 110 VDC 0.35 A 12 VAC 2.5 A 110 VAC 0.5 A 24 VDC 4.5 A 220 VDC 1.1 A 24 VAC 5 A 230 VAC 1.0 A 60 VDC 14 A 415 VAC 2.7 A 60 VAC 8.8 A UB = operating voltage IBmax = operating current |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |