23 / 35 page ![]() 23 System pro M compact ® Residual-current-operated circuit-breakers F 200 series/FS 201 Test of protective measure Except for the operating test, the effectiveness of the protection provided within the installation must be tested according to the applicable codes of practice. For RCD protection, the maximum permissible earthing resistance values are as follows: max. max. earthing resistance touch at nominal residual current voltage UL 10 mA 30 mA 100 mA 300 mA 500 mA 25 V 2500 833 250 83 50 50 V 5000 1666 500 166 100 Malfunctioning The high-quality STOTZ residual-current-operated circuit-breakers are thorougly adjusted and tested in our works. Where damage occurs (caused e.g. by transport, storage, etc.) no repair work must be undertaken. If the device responds immediately after putting the RCCB into operation, check the downstream active circuit and any connected current- consuming apparatus for earth fault current. Remove insulation faults or connections between the neutral conductor and the protective conductor existing in load circuit. Where the RCCB does not trip in the first operating test after pressing the test button, check first wheth- er the test circuit is connected correctly. Where none of the above causes apply, or should the operating test be completed unsuccessfully, the RCCB must be replaced. Opening the device will lead to a loss of warranty. TN-S system (protective multiple earthing) separate neutral and protective conductors throughout the network TN-C-S system neutral and protective conductor (PEN) combined in one part of the network. TT system IT system The residual-current-operated circuit-breaker trips if a double fault occurs, as e.g. is indicated as fault 1 and fault 2 above . Examples for the protection against electric shock I„insulation“ C„combined“ PE and N (PEN) S„separated“ PE and N „…“ terms used in international IEC standard only indicated by line isolation monitor Explanation of type codes L1, L2, L3 „line“ phase conductor PE „protection earth“ N„neutral“ PEN PE and N combined T„terre“ direct bond to earth |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |