4 / 8 page ![]() REV. A –4– TMP17 THEORY OF OPERATION The TMP17 uses a fundamental property of silicon transistors to realize its temperature proportional output. If two identical transistors are operated at a constant ratio of collector current densities, r, then the difference in base-emitter voltages will be (kT/q)(ln r). Since both k, Boltzmann’s constant, and q, the charge of an electron, are constant, the resulting voltage is directly Proportional to Absolute Temperature (PTAT). In the TMP17, this difference voltage is converted to a PTAT current by low temperature coefficient thin film resistors. This PTAT current is then used to force the total output current to be pro- portional to degrees Kelvin. The result is a current source with an output equal to a scale factor times the temperature (K) of the sensor. A typical V-I plot of the circuit at 125 C and the temperature extremes is shown in TPC 4. Factory trimming of the scale factor to 1 µA/K is accomplished at the wafer level by adjusting the TMP17’s temperature reading so it corresponds to the actual temperature. During laser trim- ming, the IC is at a temperature within a few degrees of 25 C and is powered by a 5 V supply. The device is then packaged and automatically temperature tested to specification. FACTORS AFFECTING TMP17 SYSTEM PRECISION The accuracy limits in the Specifications table make the TMP17 easy to apply in a variety of diverse applications. To calculate a total error budget in a given system, it is important to correctly interpret the accuracy specifications, nonlinearity errors, the response of the circuit to supply voltage variations, and the effect of the surrounding thermal environment. As with other electronic designs, external component selection will have a major effect on accuracy. CALIBRATION ERROR, ABSOLUTE ACCURACY, AND NONLINEARITY SPECIFICATIONS Two primary limits of error are given for the TMP17 such that the correct grade for any given application can easily be chosen for the overall level of accuracy required. They are the calibration accuracy at +25 C and the error over temperature from –40 C to +105 C. These specifications correspond to the actual error the user would see if the current output of a TMP17 were converted to a voltage with a precision resistor. Note that the maximum error at room temperature or over an extended range, including the boiling point of water, can be read directly from the Specifications table. The error limits are a combination of initial error, scale factor variation, and nonlinearity deviation from the ideal 1 µA/K output. TPC 1 graphically depicts the guaranteed limits of accuracy for a TMP17GS. The TMP17 has a highly linear output in comparison to older technology sensors (i.e., thermistors, RTDs, and thermocouples), thus a nonlinearity error specification is separated from the absolute accuracy given over temperature. As a maximum deviation from a best-fit straight line, this specification represents the only error that cannot be trimmed out. Figure 2 is a plot of typical TMP17 nonlinearity over the full rated temperature range. TEMPERATURE – C 0.2 0.1 –0.3 –40 105 –25 025 70 0 –0.1 –0.2 TYPICAL NONLINEARITY Figure 2. Nonlinearity Error TRIMMING FOR HIGHER ACCURACY Calibration error at 25 C can be removed with a single tem- perature trim. Figure 3 shows how to adjust the TMP17’s scale factor in the basic voltage output circuit. + – TMP17 + – VOUT = 1mV/K R 100 950 +V Figure 3. Basic Voltage Output (Single Temperature Trim) To trim the circuit, the temperature must be measured by a refer- ence sensor and the value of R should be adjusted so the output (VOUT) corresponds to 1 mV/K. Note that the trim procedure should be implemented as close as possible to the temperature for which highest accuracy is desired. In most applications, if a single temperature trim is desired, it can be implemented where the TMP17 current-to-output voltage conversion takes place (e.g., output resistor, offset to an op amp). Figure 4 illustrates the effect on total error when using this technique. TEMPERATURE – C 1.0 0.5 –40 105 –25 025 0 –0.5 –1.0 ACCURACY WITHOUT TRIM AFTER SINGLE TEMPERATURE CALIBRATION Figure 4. Effect of Scale Factor Trim on Accuracy |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |