STLD20CP1 Arkusz danych(PDF) 11 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STLD20CP1 Arkusz danych(HTML) 11 Page - STMicroelectronics |
|
11 / 19 page ![]() STLD20CP1 Application information 11/19 current reaches 5%. The eleventh pulse sets the LED current back to ILED max. Figure 8 shows a timing diagram for single-wire pulse dimming. Analog dimming can be achieved by connecting a resistor network to the FB pin (Figure 9). 6.3 Peak inductor current limitation and soft start function An integrated current sensor will sense the peak drain current of the switch P_SW in order to keep the inductor current below its saturation level. Since the peak drain current exceeds the fixed limit IPK by the drain current reference, the comparator turns off the switch P_SW. During start up, this peak drain current limitation behaves inherently as a soft-start function. 6.4 Charge pump The charge pump includes soft-start circuitry to limit inrush current at turn-on or when the device changes operation from x1 to x2. During the soft-start time, the output current is set to 10% of the maximum set by RTH or RFL (depending on the state of the SEL pin), until VFB_CP reaches regulation. This function is implemented to avoid battery stress. At start-up, the pin OUT_CP goes to VIN, working in an x1 condition. Following this phase, if VFB_CP >150 mV, the LED current is regulated and the device continues to operate in a 1x condition. Otherwise, if VFB_CP <150 mV, the device changes to a 2x operating condition bringing VOUT_CP>VIN. allowing LED current regulation. The device will change back to 1x mode when the input voltage rises above VOUT_CP by approximately 50 mV. 6.5 Current on power LED (flash) The current that level flowing through the power LED in both modes (torch and flash) can be selected using the following formula: IFLASH = K (0.6/RFL), ITORCH = K (0.6/RTH) where K is a value of approximately 1220. Figure 10 shows the relationship between the TF signal control and flash duration time for one camera shot, while Figure 11 represents multiple shots. 6.6 Over-voltage and short-circuit protection In case of open-circuit failure of the power LED, the output voltage is limited to about 5.5 V by gating the charge pump on/off. If the power LED experiences a short-circuit or if the output charge pump is grounded, the charge pump is turned off. 6.7 Start-up procedure Before inserting the driving preferences with the digital pins it is mandatory to turn on the device with correct supply voltage with all the digital pins set to GND. |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |