49 / 68 page ![]() Data Sheet AD5560 Rev. D | Page 49 of 68 The AD5560 has three compensation modes. The power-on default mode is SAFEMODE enabled. This ensures that the device is stable into any load. Use Compensation Register 1 to configure the device for autocompensation, where the user inputs the CDUT and ESR bits, and the AD5560 chooses the most appropriate compensation scheme for these load conditions. Table 20. Compensation Register 1 Address Default Data Bits, MSB First 0x4 0x0000 Bit Name Function 15 14 13 12 CDUT[3:0] Use these control bits to tell the device how much capacitive load there is so that the device can optimize the compensation used. Do not overestimate CDUT because this can cause oscillations. Underestimating CDUT gives suboptimal but stable performance. CDUT CDUT Min CDUT Max 0 0 nF 50 nF 1 50 nF 83 nF 2 83 nF 138 nF 3 138 nF 229 nF 4 229 nF 380 nF 5 380 nF 630 nF 6 630 nF 1.1 µF 7 1.1 µF 1.7 µF 8 1.7 µF 2.9 µF 9 2.9 µF 4.8 µF 10 4.8 µF 7.9 µF 11 7.9 µF 13 µF 12 13 µF 22 µF 13 22 µF 36 µF 14 36 µF 60 µF 15 60 µF 160 µF 11 10 9 8 ESR[3:0] Use these control bits to tell the device how much ESR there is in series with CDUT so that the device can optimize the compensation used. Do not underestimate ESR because this can cause oscillations. Overestimating ESR gives suboptimal but stable performance. ESR ESR Min ESR Max 0 0 mΩ 1 mΩ 1 1 mΩ 1.8 mΩ 2 1.8 mΩ 3.4 mΩ 3 3.4 mΩ 6.3 mΩ 4 6.3 mΩ 12 mΩ 5 12 mΩ 21 mΩ 6 21 mΩ 40 mΩ 7 40 mΩ 74 mΩ 8 74 mΩ 140 mΩ 9 140 mΩ 250 mΩ 10 250 mΩ 460 mΩ 11 460 mΩ 860 mΩ 12 860 mΩ 1500 mΩ 13 1500 mΩ 2900 mΩ 14 2900 mΩ 5400 mΩ 15 6400 mΩ 10,000 mΩ 7 SAFEMODE SAFEMODE = 0 overrides values in Compensation Register 1 to make the force amplifier stable under most load conditions. This mode is useful if it is unknown what the DPS is driving, but it does result in an extremely slow response. The default operation on power-on or reset is SAFEMODE. SAFEMODE settings are always gm[1:0] = 2, RP[2:0] = 0, RZ[2:0] = 0, CC[3:1] = 111, CF[2:0] = 5, and CC0 = 1. Set this bit high to enable autocompensation. 6:0 Reserved Set to 0. |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |