AN2713 Arkusz danych(HTML) 37 Page - STMicroelectronics |
|
37 / 40 page ![]() AN2713 Software installation Doc ID 14431 Rev 1 37/40 If the PCL checkbox is checked, a simple output short-circuit current clamp is set. If not, the overcurrent protection circuit works dynamically: as soon as an overload is detected, the output current is provided for 90 ms (typ.), after which the output is set in shutdown for a time TOFF of 900 ms (typ). Simultaneously, the diagnostic OLF I2C bit of the system register is set high. This feature allows the reduction of the total power dissipation during an overload or a short-circuit condition: ● EN=1, PCL=1 ● Vout=13.4 Vtyp Figure 37. PCL deactivation |
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|