| Zakładka z wyszukiwarką danych komponentów |
|
AN1296 Arkusz danych(PDF) 2 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN1296 Arkusz danych(HTML) 2 Page - STMicroelectronics |
|
2 / 8 page ![]() Results AN1296 2/8 Doc ID 8159 Rev 3 1 Results Three kinds of loads have been used during the tests. ● Valve ● Pump ● Resistor rated at 5 W, 150 Ω 1.1 Valve The valves used were rated for 120 V, 50 mA, 60 Hz operation. Two different types of behavior can appear during ring wave test when using such valves. ● The valve insulation is sufficient: when the ACS turns on, the current is limited by the load inductor. Only a capacitive current (approximately 250 mA peak, see Figure 2) can be seen during the rise of voltage across the switch. Such a turn on is not stressful for the device. Figure 2. 3 kV surge with a well insulated valve Vout (200 V/div) Iout (0.5 A/div) |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |