20 / 21 page ![]() AD7992 –20– REV. PrH PRELIMINARYTECHNICAL DATA Mode 2 - This mode allows a conversion to be automatically initi- ated anytime a read operation occurs. In order to use this mode the command bits C2 - C1 in the Address Pointer Register shown in Table II must be programmed. The command bits C4 and C3 are not used and should contain zeros at all times. To select a channel for conversion in this mode, set the corresponding channel command bits in the Address Pointer byte, see Table XIII. To select both Analog inout channels for conversion in this mode set both C1 and C2 to 1. When all four command bits are 0 then this mode is not in use. Figure 13 illustrates a two byte read operation from the Conversion Result Register. First ensure that the Address pointer is pointing to the conversion result register. When the contents of the Address Pointer Register are being loaded, if the command bits C2 or C1 are set then the AD7992 will begin to power up and convert upon the selected channel(s), power-up will begin on the fifth SCL falling edge of the Address Point Byte, see point A Figure 17. Table XIII shows the channel selection in this mode via the command bits, C1 and C2 in the Address Pointer Register. The wake-up and conversion time together should take approximately 3 µs, and the conversion begins when the last Command bit, C1 has been clocked in mid- way through the write to the Address Pointer Register. Following this, the AD7992 must be addressed again to tell it that a read operation is required. The read then Figure 17. Mode 2 Operation Table XIII. Channel Selection in Mode 2 C2 C1 Analog Input Channel 0 0 No Conversion 0 1 Conversion on VIN1 1 0 Conversion on VIN2 1 1 Conversion on VIN1 followed by Converion on VIN2 takes place from the Conversion Result register. This read will access the result from the conversion selected via the command bits. If the Command bits C2, C1 were set to 1,1, then a four byte read would be necessary. The first read accesses the data from the conversion on VIN1. While this read takes place, a converion occurs on VIN2. The second read will access this data from VIN2. Figure 18 illustrates how this mode operates. After the conversion result has been read and if further read bytes are issued the ADC will continuously convert on the selected input channel(s). This has the effect of increasing the overall throughput rate of the ADC. When operating the AD7992-1 in Mode2 with Hs-Mode, 3.4 MHz SCL, the conversion may not be complete be- fore the master tries to read the conversion result, if this is the case the AD7992-1 will hold the SCL line low after the read address during the ACK clock, until the conver- sion is complete. When the conversion is complete the AD7992-1 will release the SCL line and the master can then read the conversion result. 9 1 1 A SCL 9 S 7-BIT ADDRESS WA COMMAND/ADDRESS POINT BYTE A SDA Sr 7-BIT ADDRESS RA FIRST DATA BYTE (MSBs) A SECOND DATA BYTE (LSBs) A SDA 1 1 9 SCL 9 9 Sr/ P 8 ACK BY AD7992 ACK BY AD7992 ACK BY AD7992 ACK BY MASTER NACK BY MASTER |
|
|
Link URL |
| Czy Alldatasheet okazała się pomocna? [ DONATE ] |
O Alldatasheet | Reklama | Kontakt | Polityka prywatności | Link do karty katalogowej | Linki | Lista producentów All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |